Mend > Home Heating Systems

Mend Glow-worm Compact 80E Water Diaphram Valve

slight leak on d.h.w.switch?

what is the cause of a slight water leak from the front of the diaphram valve on the d.h.w.side. Leak is from where the plunger that makes the switch comes through the brass nut.The boiler is a glow-worm compact 80e combi boiler

Peter O'Hare
May 2006
This is a common problem, it is usually caused by a build up on the spindle causing the rubber seal to wear. you can replace the brass unit by turning the water off (black tap on 15mm pipe under boiler)and opening all the hot taps then undo the 4 screws and remove. Replace with new unit (around £20). Check that the water has not entered the microswitch, if in doubt replace this as well.

Ian
May 2006

Automatic Answer

We may have found other answers which could help you.

Click here for Water Diaphram Valve

Related Questions ...

Mend home heating radiators thermostat
1

problems with the 80e?

the hot water isnt getting very hot even though the thermostat is turned up full and at the same time the radi... [Read more]
Mend boiler pressure flashes
1

how can i find out about my vokera boiler?

have a vokera boiler pressure ok but flashes 04 code gas board fitted new gas valve and flue but no joy then t... [Read more]
Mend valve combi mffi
1

is there a gasket seal,between flanges of diverter valve?

hi,i have a euro coMBI a23 mffi. 1.have problem with hot water,have changed dhw switch pin,still same.obtaine... [Read more]
Mend boiler diverter valve hot water
1

replacing the diverter valve diaphram?

i think i need to replace my worcester bosch 240 diverter valve diaphram as im only getting hot water and no h... [Read more]
Mend hot water quattro boiler
1

hot water?

Hi i have a halstead quattro and when boiler demands hot water the rads are getting hot.I changed the diaphram... [Read more]
Mend valve diaphragm halstead
1

halstead ace diverter valve?

Hi this is my first time, so here i go. my diverter valve pin is not pushing out does this mean i need a new o... [Read more]
Mend Vaillant Heat Exchanger Diverter Valve
6

vaillant ecomax 824e flashing e20,e13,f20. How to fix it?

Thing is, that my boiler (which is vaillant ecomax824e) use to go through these codes e20 and then f 20, or e1... [Read more]
Mend boiler thermistors diverter valve
2

Heating/Hot Water Problems with Ravenheat RSF100ET?

Hi Original problem was not very hot DHW, but burner running flat out. Changed both DHW and CH thermistors, ... [Read more]
Mend central heating diverter valve service kit
1

ace high boiler problem?

replaced diaphram and diverter valve service kit , ch working ok , in dhw only mode both central he... [Read more]
Mend boiler heat exchanger diverter valve
1

alpha 280e problem?

hello guys . this boiler has started screaming when the heating fires up ,and when hot tap ran . took cover of... [Read more]
Mend boiler heating chaffoteaux
1

chaffoteaux and maury boiler, no hot water?

How do I replace the diaphram 3 way valve.
Mend combi pressure loss hot water
1

Hello all, boiler not working properly?

Hello all, i have a very old combi c.h boiler (solaire model ghb 21/f t.02) which no one has heard of, i would... [Read more]
Mend diaphram luke warm
3

halestead ace boiler?

hi all i descaled the heat exchanger and replaced the diaphram but still have luke warm water. the valve actua... [Read more]
Mend boiler central heating hot water
2

Baxi Combi 80Eco no DHW?

Hello, I have recently bought a house with a relitively new central heating system. The boiler is a Baxi Co... [Read more]
Mend combi boiler faulty ignition
1

how to tell if gas vavle is faulty?

my Jaguar 23k combi is not igniting although you can see the ignition sparking it displays F1 recently replace... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...