Recent: Safely remove screen protector from a Macbook Air?

Mend > Home Heating Systems

Mend Worcester 24i Boiler Combi

worcester 24i combi boiler?

i asked this question earlier and 'john' gave me an answer.
john if you're reading this would you take the time to quickly go back to my initial question and see what i wrote, saves me having to re-write it all again?

chris gray
February 2010
well come home to a nice hot house and fully functional boiler. i now have a expansion vessel on the floor attached to the flow side of my c/h, its not the bonniest of things but at least it works.
and for £50 which is what hes charged me we're both winners.

ive just reread my whole dilemma and think that this all may be of use to someone else in the future. chances are they wont read this far back and it will be lost to the archives.
cheers and thanks again john

chris gray in his heated home
March 2010
yeah i got a plumber tomorrow, hes going to just stick another vessel on below the combi, as the worcester one is at the back and a chunk of work to swap over.
thanks for your advice mate.
i wired his en-suite up sometime ago and did it for mates rates, so hope he's going to return the favour when it comes to payment.

chris gray chanting 'british jobs for british workers'
February 2010
well done mate, you have self diagnosed, best to let the experts change the vessel, its a rotten job, worcester offer a prompt and reasonable repair service and will give you three major parts for a fixed fee, so if other things go wrong during the repair they have parts on board, also they will change the auto air vent and prv while there as the engineers loose money if they have , recalls

john
February 2010
cheers john
emptied the vessel, pumped some air into it, repressurised back upto 1.2bar, and called for c/h, the gauge slowly goes up. turned it off and left it last nite.
went to it this morning and the gauge had fallen to .4 bar and there was no air in the vessel.
going to have a new vessel fitted tomorrow.

chris gray stalking john
February 2010
the amount of pressure in the vessel isnt critical, if you push the tyre pin and it hisses and you have pumped it and expelled any water that may have been within that is somewhere near good enough. if your pressure gauge isnt working now that suggests to me dirt or sludge has blocked the pin hole within the nut that connects the copper wire between the gauge and boiler, if you totally drain the system and undo that nut and try to clear you have a chance of reusing it, there is only so much advice to be given in a situation where the boiler cant be seen, if your system is heavily sludged then that may be the cause of all the problems up to now and will require flushing and cleaning.as an after thought are you sure the point where you are filling the boiler isnt continuing to let by once you think it has turned off and causing the boiler pressure to go too high? disconnect once filled if unsure to inspect. good luck, i hope this helps

john
February 2010

Related Questions ...

Mend Worcester Combi Ignition
2

Worcester 30 Cadillac combi boiler won’t fire up and the EA?

my worcester 30 cdi combi combi boiler wont fire up and ''ea'' keeps flashing? my worcester 30 cdi combi bo... [Read more]
Mend Worcester Bosch Combi Boiler Home Heating
1

Worcester Bosch 532/i Combi Boiler?

worcester bosch 532/i boiler. when the hot tap calls for water the boiler runs ok heating up the water to the... [Read more]
Mend worcester combi boiler
1

Worcester botch combi boiler?

Worcester combi making a gurgling noise then cuts out
Mend Worcester Bosch Heating Hot Water
1

How do I rectify aU9 Code?

Worcester Bosch Greenstar 37CDi Combi showing code U9? My boiler is showing code U9, I know this means that th... [Read more]
Mend Worcester Combi Heating
1

Worcester boiler problem?

I have U2 code on Worcester combi boiler…
Mend boiler combi repair
1

worcester 240 combi boiler?

can I repair siezed pump. motor still trying to run
Mend thermostat boiler fault
1

Which model room thermostat do I need?

I have a Worcester Green Star 37cdi combi boiler. The room thermostat controller is showing an E1 fault so I ... [Read more]
Mend boiler heating temperature
2

Worcester Bosch Greenstar Ri v Beast from The East?

My boiler has been struggling to reach thermostat temperature and has now started gurgling like its boiling a ... [Read more]
Mend boiler radiators pressure
2

I only have heating downstairs... ?

Hi all. My heating has been a bit funny. The radiators upstairs aren't heating up at all and the ones downstai... [Read more]
Mend combi boiler no hot water home heating
2

worcester24i rsf?

worcester 24i rsf combi boiler.no hot water when i turn hot water taps on heating is ok
Mend pressure worcester heat
1

Faulty Worscester 35 CDi loosing pressure?

My Worcester 35cdi has had 4 replacement heat exchanger's in less than 10 years the first 2 were within the fi... [Read more]
Mend combi boiler pressure air lock
2

How can I stop my Worcester 24i from building up too much pressure ?

My Worcester 24i combi boiler has just started to build up pressure beyond the blow off valve setting (IE. in ... [Read more]
Mend boiler heating thermostat
1

combi oil Worcester greenstar heatslave 12/18 switches off?

I have a internal combi oil Worcester greenstar heatslave 12/18 Its has a built programmer and Hot water t... [Read more]
Mend boiler override heating worcester
2

Boiler override if roomstat fails?

How can I run the boiler for heating if the roomstat fails? Is the some sort of override function on the boil... [Read more]
Mend boiler heating Worcester
1

Worcester 28i Junior combi boiler Suspect Fan Fault?

Worcester 28i Junior combi boiler Suspect Fan Fault?

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.