4 hours ago: Trayford close coupled toilet?

Mend Home Alarm Systems

Mend Security Systems, Home Alarm Systems
Find out how to mend it for free.

Ask Question
Mend Security Systems, Home Alarm Systems
Mend repair fix home alarm systems

Related Categories

Mend Car Alarm Systems
Car Alarm Systems

Mend > Home Alarm Systems

Mend Security Systems, Home Alarm Systems

how do i reset alarm after accidently setting of tamper switch?

I have just inherited a Modern Security Systems Series 3200 alarm in a shop i have rented and whilst renovating the shop set off the tamper switch on one of the control panels. I put the code in which silenced the alarm but it now shows R1 flashing which i believe relates to the control panel tamper. How do i get rid of this so that i can use the alarm again. Also how do i change the code? Hope someone can help. Is there an easy way to get a user manual for this system? Thanks

Jason
February 2010
my alarm says ef, how do i reset my alarm so i can use it and also if anybody knows how ef would have came on my alarm in first place.

many thanks

brodi
November 2010
Acorn why is it we find ourselves answering the same questions over and over again. I wish people would read previous posts.
Regards
Nick

Nick
February 2010
Just to help a bit, the Modern Security Systems Series 3200 is a re-badged Scantronic 9800, I would be very surprised if you were able to find the Series 3200 manual, so look for the 9800.

By the way there is not an R1 error code for this panel, look again.

Have a look below, upper and lower case are important -

c1 to 8 Detector circuit open.
t1 to 8 Circuit tamper open.
o1 to 8 Detector circuit omitted (isolated).
E1 to 8 Entry via a detector circuit.
S1 to 8 Detector circuit on Soak test.
EA Alarm on entry
EF Exit fault
bF Control panel battery fault
PF Mains supply failure.
Sr System reset (Total power failure).
AP Aux. (Detector) power failure.
Lb Control panel low battery.
rt Illegal use of keypad (excess number of keypresses).
rP Remote keypad missing.
rr Total power failure (engineer reset required).
u1 to u9 User access number (U5 = Duress, U9 = Keyswitch)
AE Access Engineer
AA Arm area A (Full set).
Ab Arm area B (Part set).
Ac Arm area C (Part set)
Lt Control panel tamper.
tr External bell tamper.
cF Communications failure (External signalling).
LF Telephone line fault.
cc Communications completed successfully.

Post here again, let's see if we can help some more.

acorn
February 2010
Mend Security Systems, Home Alarm Systems
Mend repair fix home alarm systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Security Systems, Home Alarm Systems
Mend repair fix home alarm systems