Recent: Home max fs506x?

Mend > Home Heating Systems

Mend Baxi 24HE Combi Boiler Heating Fault Intermittent

Baxi duo tec combi 24HE heating fault?

My 2 1/2 year old Baxi combi shuts down the heating side despite everything calling for heat. This happens intermittently for no apparent reason and I usually discover it when the rads have gone cold! Despite being 'off' something is still running, pump or flue fan? I have to switch the main electricity switch to the boiler off and on again to rectify the problem, the boiler then firing up as normal. The hot running water side is not affected.

Troubled John
January 2010
hot water working , central heating not. any ideas? thanks

tony beno
March 2013
i have baxi duo tec 2 28ga installed in my home. my central heating is working properly but not hot water is coming. can anyone help?

awi
July 2012
How do i change the PCB in my baxi duo tec 33, fault E168.

APB
January 2011
there is a return filter fitted inside the nut on the jig /pipe connections //to do this and check for debris and sludge you need to isolate the 2 black taps under boiler black tap furtherst left and black tap furtherst right inside the boiler to the right of the pump is a small white wheel valve open up and drain boiler into bucket underneath you will get about a 5th of a bucket then when water stops undo the silver 1/2 " nut on the return pipe this is found above the right hand black tap you have isolated it sits facin you underneath remove and check for crap // when complete refit open taps and re pressure to 1.5 bar

tony
January 2010

Related Questions ...

Mend boiler diverter valve intermittent fault
1

Baxi Combi Instant HE80 boiler?

Intermittent fault on the hot water. Sometimes it comes on but when it doesn't I can sometimes get it on by tu... [Read more]
Mend boiler heating fault
1

worcester 350 combi 10 years old two pumps?

the pilot lights but the flame doesn't spread across the burner to the flame sense electrode this happens on b... [Read more]
Mend combi diverter valve heating
1

No hot water & central heating - Sime Super 90 combi boiler?

Combination boiler is 9 years old, no hot water or central heating. When hot tap turned on switch clicks but p... [Read more]
Mend combi boiler central heating faulty
2

how to fix my vaillant turbomax plus 282/2e combi?

re: vaillant turbomax plus 282/2e combi boiler. Problem with c.h coming on when internal timer in 'off' and ro... [Read more]
Mend boiler heating fault
51

Ravenheat CSI 85AT boiler tripping problem?

Ravenheat condensing combi boiler CSI 85AT fault? My 1.5 year old boiler has developed a random & intermitt... [Read more]
Mend boiler fault pressure
4

Ravenheat condensing combi boiler CSI 85AT fault?

My 1.5 year old boiler has developed a random & intermittent tripping fault, in both modes of heating (i.e. CH... [Read more]
Mend combi pressure heating
2

Intermittent hot water one SIME combi boiler?

I have a sime combi boiler, sorry, I dont know where to find the model number, but the heating (radiators) are... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.