Recent: Will I need to replace my garden tap?

Mend > Home Heating Systems

Mend Drayton Digistat 2 Boiler Faulty Heating

Drayton Digistat 2 not working?

my sender unit appears to be working OK(flame when temp above room temp) but boiler doesn't fire.
Receiver unit shows steady red light against "receive"alarm.
have tried to reset per query Jan 09 but no difference.Boiler fires manually via override button.
Are units faulty & need replacing or is there anything else I can try?

stevieg
October 2009
I had the same problem and Craigs remedy worked perfectly.
I can get kids out of bed in the morning again now

paul
December 2009
Craig, you are a genius

Peter Johnson
November 2009
hi i was wondering if you could help me i've got a sony bravia 50inch KDF-E50A12U tv. the red led light is on constant then i have another red light which also flashes green

Ricky
November 2009
1. Turn off the power supply to the Digistat SCR (receiver unit)
and leave for 5 seconds.

2. Turn on power to SCR unit and check red light is on
.
3. Press override button No.2 and check the green light comes
on and boiler fires.

4. Press & hold down button No.1 (Keep depressed), then
press No.2 and keep depressed. The Red LED light will flash
a couple of times and then it will go out

5. Now release both the buttons – the two LED lights should
come back on.

6. Get the Digistat unit and stand two metres away
from the SCR unit with the Digistat unit in your hand.

7. Remove the batterys cover and wait for the display to fade then fit the batteries in the right hand drawer first.

8. The Red LED light on the SCR will now flash for approx. 7
seconds.

9. This confirms that the radio signal is being sent and
received.

10. The Digistat and the SCR are now successfully
linked.

craig
November 2009

Related Questions ...

Mend boiler heating fault
1

Home heating systems?

Further fault Glow-Worm F100 gas boiler. When the boiler starts up the burner flame comes through the pilot l... [Read more]
Mend boiler condensing boiler faulty
2

Faulty Ravenheat condensing boiler?

My Ravenheat CSI primary condensing boiler will not fire up. I called out a heating engineer who diagnosed a f... [Read more]
Mend boiler pcb condensate
1

Faulty vokera compact 25?

I have spoken to the gas safe engineer that installed this boiler new approx. 3 years ago about the problems i... [Read more]
Mend boiler pcb fault
3

Faulty vokera boiler compact 25?

Hi this boiler is doing my head. I have no hot water or heating, sometimes the boiler will fire up if set low... [Read more]
Mend heating thermostat combi
1

ideal combi 30 boiler heating not working on timer only override?

The heating only comes on when I override the timeclock if in timer mode the timeclock keeps the correct time ... [Read more]
Mend gas boiler thermostat hot water
2

Glowworm cx30i gas boiler?

My boiler comes on intermittently when the thermostat is turned down below zero degrees. It is all running fi... [Read more]
Mend combi boiler heating overheating
1

FF 14 extra fast combi boiler?

My extrafast 96 will deliver DHW on a moderate flow but cuts out after few seconds on full flow from a single ... [Read more]
Mend central heating boiler months ago
1

how can I fix my old glow worm central heating boiler model 65-80?

several months ago the ignition on my conventional flue boiler failed to stay alight and I had an idea that it... [Read more]
Mend boiler heating fault
2

Potterton Performa 24 DHW issues?

My Potterton Performa 24 has developed a DHW fault, & I need help resolving it please. In November, it stoppe... [Read more]
Mend rid air system
2

How can I get rid of trapped air in central heating system?

After replacing the small rubber seal on the shaft of the hydraulic actuator in my BIASI 24S Combi boiler, the... [Read more]
Mend combi heating faulty
1

Main combi boiler ?

Why is my boiler sending hot water to my radiators when I only want hot water to my taps. The heating is turne... [Read more]
Mend heating boiler fault
1

How can I fix hot tap in bath. Boiler is a Compact HE?

The hot tap for the bath is running slow and goes hot and cold...I believe it may be the tap itself (The unit ... [Read more]
Mend boiler sealed system hot water
1

Grant outdoor combi 90 v3?

My sealed system loses pressure when I run the hot water. When boiler cuts in the system builds up pressure ag... [Read more]
Mend combi heating pressure
3

baxi 105e combi boiler?

boiler wont modulate when central heating is on causing pressure to exceed 2.5bar, is it the electric safety s... [Read more]
Mend combi-boiler heating fault
3

Sabre HE Combi boiler fault?

Hi, I've got a two year old Sabre HE combi-boiler. The heating and hot water is now not working. The green lig... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...