ferroli combi boiler Pressure?

I re-pressurised my expansion tank about 18 months ago using instructions below:-

1. Switch off the boiler. Ensure that there is no water pressure in the system.
2. On top of the expansion vessel (grey object with standard tyre valve on top, viewable from the top of the boiler) inflate with a bike or car pump to 1.5 bar (22 psi)
3. Charge your water system pressure to 1.0 to 1.5 bar.
4. Start your boiler

I've no problems, until this week, found i'm losing pressure again, I tried the above again but found the expansion vessel still around 1.2 bar... Any ideas? when I top the boiler up it runs at about 2.5 bar and empties when off, but does not seem to be coming out of the release pipe at the back as it did 18 months ago. Any ideas??

Chris J
October 2009
I think your EV pressure is a bit high.....usually 10 psi is about right unless the manufacturer says otherwise. If your pressure is constantly dropping, it does mean a leak somewhere.

John
October 2009
i m not sure but seems like u have a leak somewhere either on the rads or the pipe work good luck

sajeed
October 2009

Automatic Answer

We may have found other answers which could help you.

Click here for Pressure Expansion Tank

Mend Heating, Home Heating Systems
Free repair help for Ferroli home heating systems

Other models...

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Free repair help for Ferroli home heating systems