Mend Heating, Home Heating Systems

worcester 28 cdi boiler?

the pressure gage is at max 4 bars,i bled the radiators,and replaced the loop,but the pressure keeps rising to max,what else can i do ...thanks

terry
August 2009
how do i re-presurise by expansion vessel and to what pressure ?? thks

wayne
September 2009
did you manage to resolve the problem? If so, what did you do as this is happening to my boiler?

dg
September 2009
no db thats only if you get a excessive rise when system hot ie using the heating.

max rise even when cold is like mentioned below...plate exchanger

a
August 2009
had this problem myself it was the expansion vessel needed pumping up this solved mine

db
August 2009
Disconnect the Filling Loop to prove that it is not letting by, if pressure continues to rise then the Hot Water Plate Heat Exchanger is probably to blame