Recent: Home max fs506x?

Mend > Home Heating Systems

Mend Potterton Main Combi 30 HE Flame

intermitant boiler starting ?

potterton main combi 30 he , doesnt always fire up , flame failer of blocked condensate drain indicator comes on , the condersate is not blocked , press restart , occasionally fires up , sometimes takes 4 restart attempts but will sometimes fire up straight away

sarah smith
July 2009

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Main 30 Flame

Related Questions ...

Mend pilot light thermocouple thermostat
1

Pilot goes out despite replacing thermocouple?

Hello, in my TA 20/30 the pilot goes out when the main flame is switched off by the thermostat. I have replace... [Read more]
Mend boiler gas thermocouple
2

Glow worm space saver 45-60 cutting out?

My boiler cuts out after 30 seconds cutting off main gas valve so lose main burner and pilot. It had a new t/c... [Read more]
Mend boiler fault heating
2

Main combi 30 HE fault?

Hi, I have a problem with my boiler, the boiler fires in and then cuts out. then the flame indicator start... [Read more]
Mend boiler heating failure
1

main combi 24 he?

had a new curcuit board fitted, same problem with flame fail.sometimes runs for several hours with no probs, t... [Read more]
Mend main combi water pressure
2

Main combi 30 HE,have upped the water pressure now flashing flame failure?

Have bled the radiators this morning then heating stopped working,realised i needed to up the water so have do... [Read more]
Mend boiler heating spares
2

Glowworm Fuelsaver gas valve problem?

Glowworm Fuelsaver 30 - 40B. When all systems set ok, main boiler burner fires up randomly between normal flam... [Read more]
Mend warm air heater johnson and starley heating
1

how can I fix my Johnson and Starley J25-J32/Jan warm air heater?

When I turn on the room thermostat the main heating burner comes on for about 30 seconds then cuts out leaving... [Read more]
Mend boiler pcb flame
1

Potterton Suprima 50 cuts out soon after ignition of main flame?

I fixed the 'lock-out' problem last year by resoldering all the suspect joints on the PCB. After working OK f... [Read more]
Mend boiler natural gas ignition
2

How can I get my Potterton Netaheat 10/16 natural gas boiler to light?

My Potterton Netaheat 10/16 natural gas boiler is about 30 years old and has worked well and still is in good ... [Read more]
Mend boiler combi thermocouple
3

ravenheat CSI 85A combi boiler. flame blowing out soon after ignition?

boiler is 2 years old. it starts normaly (fan starts, ignition clicks, pilot comes on then main burner ignigh... [Read more]