Recent: Fix food processor motor?

Mend Chaffoteaux Combi SE Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Mend repair fix Chaffoteaux Combi SE home heating systems

Mend > Home Heating Systems

Mend Chaffoteaux Combi SE Work Water Pressure

My combi boiler wont work .... low water pressure????

Our Britony combi SE Boiler by Chaffoteaux & Maury wont switch on the fault code is saying that there is low water pressure in the central heating circuit?? Is there anything that i can do to fix it or shall i call a plumber????

Thanks

Martine Lowe
December 2005
I have a eco esprit ideal boiler its flashing L5 which I know is a reset code what do I do please the pressure needle is on 0

kerry
November 2015
Ive got a morco feb 24ed combi system,came up with low pressure for the central heating yesterday. I found the filling hose and turned the tap,but it doesnt fill up. If i disconnect the hose the water runs through,but not when the hose is connected,help please!

adam sculthorp
November 2013
Ideal combi 24 boiler: bled a top floor radiator and now flashing F1 which I think is low pressure.
Any advice on how to proceed?

Sally Heatb
April 2013
my dial wont move but im getting hot water and heating

arlene
February 2013
Low water pressure and can't find any leaks

Graham
November 2012
Don't no how to add water to my combi boiler.

Kerry munro
April 2012
my combi britony c&m chafforteau & mauray - occassionaly keep switching to red instead of amber especially when open hot tap water. would you please advice

Khris Rungien
February 2012
Absolutely fantastic answer. We'd resigned ourselves to a night with no hot water, but this fixed it in one and saved us calling out a repairman. Thank-you!

Anonanon
January 2011
It worked for me. well done Mike

Umid
October 2010
we've got same boiler, when we put heating on or run taps it drips from boiler, any ideas?

stan
September 2010
Great advice! Woke up this morning with the 40 and 80 lights flashing, found the tap beneath the boiler on the silver flexible pipe and turned the tap until the gauge read 1.5 bar. Works perfectly. Thanks

Scott
May 2010
Hi, before reading this thread I tried this but wasn't sure how much water to put in. Now I think I've put in too much. When I switch on the heating the water pressure guage rises rapidly and the boiler makes crazy sounds like it's gonna blow! How can I get the water back out of it?

(Britony Combi SE)

Chris Shamone
December 2009
Hey I had the same problem with a Saturn KDB-172FA boiler and this helped me fix it, thank you!

Theodore
December 2009
Massive help thanks guys. I had the same problem (low water pressure on the central heating circuit). Found the water pipe to manual feed water into the boiler and hey presto, hot water again!.

Mathew
February 2009
My boiler was leaking from one of the main pipes. So i drained the system and un-did the nut on the pipe and found an ole brittle washer. So i put in a new washer - re-tightend the nut - re-filled the system and hey presto. It works. The pressure keept dropping for the first day or two but this was just because it takes a while for the pump to get the water to all the rads. No more leaks. But i am suspecting that the main circuit board is on its way out as i have to keep resetting it all the time

smithykins
December 2008
Thanks so much, I just had the same low pressure problem and fixed it using your answers. Had lost the manual.

Isabel
October 2008
Does anyone know where to get a central heating water pressure switch for the Britony Combi SE80? We filled up the water pressure but I guess a little too much as this switch is now bust and we need to get a replacement. The plumber said that the manufacturer no longer supplies this part so instead of a quick £200 job we will have to get the whole boiler replaced @ £2,800. If anyone knows of anywhere we can try to find this part we would be hugely grateful. Thanks in advance!!!

Sam
October 2008
It may be that your filling set is boxed in. Mine was!! If you cannot find the flexi pipe, then remove any local pipe box sections and take a look.

Tip top tommy tiddle pop pop poo
October 2008
my friends boiler has no hot water (i take it, it wont have heating either) - it is flashing 40 & 80. low pressure, so reading all info on this page we have to find the filling loop wiv a silver hose - we will use all info from this page to try and get it sorted - thanks guys

Donna
September 2008
Hi, my son has just bought (buying) a house with this Combi and 'phoned to say he had a low pressure warning and that he had no hot water. Logged on and found this answer, telephoned my son and he had it sorted in 30 seconds. Well done Mike and all who contribute. A very big thank you.

Ketteringjimmy
August 2008
hi, my pressure is back up, half way between the red min and red max on the dial. good. still the same error though (40 and 80 flashing). i've turned it all on and off a few times, no joy. any more ideas anyone?

Graeme
August 2008
Guys thank you all, you are total stars, I was just about to give up hope and call a plumber.

James
June 2008
Mike, You're a genius. We've been puzzling over this for 24 hours over a bank holiday and were just about to call someone out when we found your instructions about the silver hose - they worked. Thank you!

Jane
May 2008
You guys are talking about the water heater side of a combi boiler for the radiaters , correct.? What if i wanted to get more water pressure outta the water heater side for say, the shower. how do i get more pressure outta that side of my combi boiler?????

joe
January 2008
fill it up using the filling loop to 1 bar

kev
November 2007
Hi I have just had the same problem, the lights 40 and 80 were flashin, so i turned the filling loop anti clock wise till it came back on, ty for your answers helped me alot, money in my pocket...ty.

steven tierney
October 2007
there shoul be a filling loop somewhere close to the boiler normally two valves with a silver hose between simple turn both valves on until your pressure gauge reads around 1 nad a half bar and turn both valves back on

mike
December 2005
fill the system to 1.2 bar by opening up the tap on the filling loop or read and follow the instructions if there is an inbuilt filling system

marco
December 2005
Underneath the boiler there is a tap which when turned will increase the water pressure in the boiler. Do not fill the boiler up too much, about a quarter should do it - cold water though.

Adam Whittaker
December 2005

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Work Water Pressure

Mend Heating, Home Heating Systems
Mend repair fix Chaffoteaux Combi SE home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Chaffoteaux Combi SE home heating systems