Glow Worm Compact 80e hot water problem - can you help?

Hi,

I can only get hot water from my Glow-worm Compact 80e combination boiler if I turn the water on full-blast. Sometimes I actually have to turn 2 taps on (basin and bath) before it even gets warm. Once warming I can usually turn off the second tap. However, the water flow is so fast it barely gets warm.
If I then gradually turn the tap off, the water does get warmer, but never hot, and well before I have turned it down to a "normal" flow it goes cold.
British Gas have had a look at it twice and have replaced a diverter valve(?) and then the engineer said that was all he could do except for flushing out my system which is chargeable over and above my service contract and would cost me £600!!! I'm flabbergasted that he can't do anything else, but I'm in no way qualified to question his diagnosis. Does anyone know if thet sounds reasonable or am I being taken for a ride?
Added to that, there's a 15mm pipe that sticks out through my wall which constantly drips when the central heating is on, and as a result my system loses pressure and needs topping up at least every other day. The BG engineer has replaced something there also but it hasn't made the slightest difference.
If anyone has any ideas of things I could suggest to him on his next visit, I would be very grateful to hear them.
Are my 2 problems related, or have I actually got 2 different problems with my boiler?
Thanks in advance to anyone who replies.

PeedOffAndy
January 2009
Hi, can you please let me know if you found a soloution to your problem as I have a glowworm compact 80e and can only get hot water when I turn two taps to get the boiler lit, and then turn one off and decrease the water pressure coming out the remaining tap until it gets slightly warm. It is becoming incredibly frustrating and I'm not sure what to do about it. Many thanks.

A
August 2012
Your blow of could be faulty or its doing its job because the expansion vessel is leaking inside try taking of the dust cap on it and quickly pressing the valve if water comes out the expansin vessel has gone

BAz
February 2009
getting it power flushed will not fix the hot water. get on the phone and tell them to get back and fix it!! - make a serious complaint, but it sound like you do NOT need a power flush.

the gasman
January 2009
Ok.. sounds like you have two faults.

Dripping pipe - faulty pressure relief valve, no air charge in expansion vessle, blockage in feed pipe to vessle.

Poor hot water - sounds to me like you have a faulty diphragm in the hot water flow switch. this can stretch causing the fault you describe.

C
January 2009
pressure relief valve leaking.

Ben
January 2009

Related Questions ...

Mend boiler leak heating
1

Overflow leak?

Combi Boiler Sime 102 Overflow pipe is leaking water in small drips even though central heating is switched o... [Read more]
Mend boiler central heating fault
2

valliant eco plus 837 boiler ?

hi i have a vaillant eco plus 837 boiler , and recently had a small pipe change for shower head to downst... [Read more]
Mend central heating leaking pressure
2

boiler pressure?

boiler pressure is rising to much on central heating side and water leaking from vent pipe
Mend central heating leak repair
1

HOW CAN I REPAIR THE WATER OUT PIPE FROM LEAKING LEAKING ?

WHEN THE BOILER IS ON CENTRAL HEATING THE PIPE WHICH GETS WARM AND ALLOWS WATER OUT LEAKS FROM I BELIEVE WHERE... [Read more]
Mend central heating boiler leak
2

Water pressure disappering?

I top my boiler(Saunier duval SD620F) up every day to have found out it is leaking from the over flow pipe out... [Read more]
Mend central heating safety valve pressure
1

domestic water safety valve leaking on Glow-worm 30 ci plus?

Water leaks out of the 10 bar domestic safety valve on my boiler when it has been on for a while, its running ... [Read more]
Mend boiler heating leak
1

HOW CAN I STOP WATER COMING OUT OF THE 15mm PIPE THAT GOES OUT SIDE FROM MY?

I HAVE A POTTERTON COMBI GAS BOILER THE 15mm PIPE THAT GOES OUTSIDE KEEPS LEAKING WATER AFTER CENTRAL HEATING ... [Read more]
Mend combi boiler leaking pressure
3

how can i fix my combi boiler?

since yesterday water has been leaking from overflow pipe outside. when i checked my ferrolli combi boiler in... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...