Recent: Fix food processor motor?

Mend Worcester Greenstar Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Mend repair fix Worcester Greenstar home heating systems

Mend > Home Heating Systems

Mend Worcester Greenstar Error Message Service

Worcester Greenstar CDi Error Message?

How do I remove the error message SE from my boiler having had a recent service?

Brian
October 2008
OK:

Press spanner button for 10 sec til lights up orange

It will say 1.a in the display

Press "eco" repeatedly til this says 5a

Press chimney sweep (man with ladder) button once, it will light up

You should see 00 in display

Press "eco" once, won't do anything but press anyway

Now press and hold chimney sweep til you see [] in display.

When you see [] let go.

It will go back to 5a.

Now press spanner once to get back to normal mode.

Voila :)

BunSlinger
October 2008
The SE error appears after 2340hrs burner operation, It is not a fault code and does no harm. Whils it can be reset the procedure is a bit long winded. I would suggest that when you have it serviced next you get the engineer to reset.

Mike
October 2008
Mend Heating, Home Heating Systems
Mend repair fix Worcester Greenstar home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Worcester Greenstar home heating systems