Double glazed upvc window is steaming up inside?

My double glazed window is steaming up. How can it be repaired?

Sue Kirby
July 2008
How fix upvc window steaming in side windiow

Fm
April 2013
We have a large double glazed pane c 900 x 1200mm that has steamed up. Why is it not possible to reuse the glass with new seals? (We are supposed to recycle/reuse, not throw away)

Chris Sc
May 2012
i have problem with steam window in living and bedroom trip grown mould on sill and wall now what i do with it?

mrs baldwin
February 2012
what has been said thus far is partly correct drilling 2 holes on its own will not solve the problem the unit needs to be cleaned the moisture evaporated and a polymer coating applied to the glass. The polymer coating is the key similar to that coating on skiing goggles or a bathroom mirror but applied in-situ. At the same time the spacer bar needs to be re-sealed to stop the now saturated silica beads from putting moisture back into the unit. All of this can be done for about 60% of the cost of a new unit. If this process is applied it carries a 20 years warranty which nobody will ever offer on a new unit. Councils and local authorities are now activelly using this solution to reduce their carbon footprint and at the same time save money. It's win win for them.

DD
September 2010
i have manufactured double glazed units for 25 years ,and i can tell you that these companies that claim to repair your steamed up double glazing by drilling holes in them ,are conmen!!!
once a dgu has failed , that means the seal has been compromised.
there is nothing short of gods intervention that will reseal a dgu !
it has to be replaced with a new unit .
nowadays units are made to last, as the sealants have moved on to hotmelt, which is more resiliant to moisture than the old two part rubber compounds. a normal dgu measuring 1000mm x 1000mm would cost no more than £25 to buy...in toughened about £35...in low e glass , about £30..and leaded add another £20 ....but i would recommend you get a small company to do it , as there is more to it than that ...like the correct size , the correct cavity , and the handling of course ...i usually charge no more than £100 to replace a unit 1 metre square

STEVE..07936460559
August 2010
Tradespeople will always suggest you buy a new unit.
There are many firms now who claim to get rid of the mist from between failing double-gazed windows: they do this by drilling two small holes ~ 3mm, one near the top and the other near the bottom of the outer pane. They then fit tiny grommets with a net filter.
It seems to me you have nothing to loose by trying something similar on your unit
Personally I would drill the two holes on the INSIDE and after a few days when the mist had disppeared, fit small nylon plugs to prevent contamination

GJK
September 2008
iv fixed units before but its a hassle,when the unit is removed you will see a coating of black rubber solution,this usualy cracks and lets the water in to cause condensation.on a property i was developing the budget didnt allow me to replace so i removed all the units strippd back part of the rubber and dried them out then reseald with black silicone,done the trick,if moneys not a problem replace it.

ron
July 2008
it is a failed unit and a replacement is needed. a 10yr guarantee is normally provided by the double glazing company so check on this

levi lewy
July 2008
sadly you cant repair a double glazed unit,you will have to replace it with a new one,the best way is to get a glazier in your area to do this as you have to mesure the unit correctly in height,width and thickness and with new regulations it may have to be toughened or energy efficient glass or both,then you have to replace it and its a bit tricky to do,so if you replace it and break it you will have to pay for another if a glazier breaks it it will be him who has to pay for it.hope this helps

shaun www.sdwupvcrepair.co.uk
July 2008

Related Questions ...

Mend How to mend it?
1

Can you open a double glazed upvc window?

Hi. I’m wondering whether you can remove fake plastic leaded light from the middle of a double glazed wind... [Read more]
Mend windows lock double glazed
1

Window lock spindle?

Spindle stuck in double glazed window and magnet will not draw it out. What else can Indo?
Mend bar window glazed
1

Seized double glazing locking bar?

I have an upper small window in a large double glazed bedroom window. Having not been opened for a while it se... [Read more]
Mend double unit allow
1

Corrosion in between double glazed unit?

Recently we had to have a double glazed unit in our porch removed to allow a settee in through the window into... [Read more]
Mend double glazed condensation
1

How easy is it to fix a cracked window on a upvc unit?

I've got a double glazed window in a upvc unit that has a crack on the outside so condensation building up bet... [Read more]
Mend How to mend it?
1

cracked double glazed window?

How can i fix a cracked double glaze window. My children throw a hard ball on the window and it cracked.
Mend that close top left
1

how can i fix a upvc top hung window that does not close snugly on top left?

how can i fix a top hung double glazed upvc window thay does not close tightly on top left hand corner
Mend double glazed unit replace
1

window won't close properly?

My double glazed window unit fails to engage when closing, it appears to be slightly ''off the upright'' . . ... [Read more]
Mend double glazed units
1

replacing georgian leaded double glazed units?

Hi, several double glazed units in my house which are georgian leaded have failed and need to be replaced, h... [Read more]
Mend replacement repair upvc
1

Replacement UPVC window door frame?

Locked myself out of house. I broke the exterior UPVC double glazed window frame in the rear door. Glass came ... [Read more]
Mend mechanism double window open
1

locking mechanism?

my double glazed window wont open it seams that the locking mechanism is disengaging the top half but not the ... [Read more]
Mend clean door replaced
2

How can I clean my door?

I had a window replaced last April with a customised double-glazed, UPVC, designer glass patio door, leading ... [Read more]
Mend rubber help stops
1

The rubber seal around my double glazed window keeps popping out. Help!?

Is there something I can do to make sure this stops happening?
Mend double glazed window
1

how can I fix a double glazed window?

The window is stuck on open and we are unable to shut it again. Any suggestions on how to repair it please?
Mend window double glazed top
1

How can I shut my jammed window?

I have a double glazed window that I have opened it seems too far and now it won't shut. It is completely stuc... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Windows and Doors ...