Recent: How can i mend my Aiwa HV-FX7700K?

Mend Glow-Worm Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Find out how to mend Glow-Worm home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

how can ifix my Glow-worm?

I have an e40 glowworm. The pilot light went out. I put it back on. Now when i put on the main burner the whole thig cut out after 20 mins. if i just leave the pilot light running then it is fine. Please help!!

Gary
August 2005
The pilot light may be a little low so that the thermocouple is only just hot enough to prevent the system from cutting out. When the pilot light is on on its own, the pressure will be slightly higher and the draft will be less, allowing the thermocouple to remain sufficiently hot.

When the main burner is on, the gas pressure will drop slightly and there may be an additional draft, which could cause a slight drop in the temperature at the thermocouple.

In time the thermocouple output may drop enough to cause the system to cut out completely. This would lead to both the main burner and pilot light being extinguished.

If this sounds like your problem, you could try increasing the strength of the pilot light flame by a small amount - there is a regulator somewhere in the main gas valve.

Dealing with gas is potentially lethal, so you should not attempt any repairs unless you have complete confidence in your capability.

Henry
October 2005

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Glowworm Pilot Light

Mend Heating, Home Heating Systems
Find out how to mend Glow-Worm home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Find out how to mend Glow-Worm home heating systems