The switch which controls the water is made of plastic and normally stops working after some time.I had the same problem last month.Unclip the pipe by pulling it away from the valve after shutting the mains water supply to the boiler. Use a needle or small screwdriver and push the ball down, make sure you have unwinded the valve first.Connect the pipe back on and turn the water supply it should do the trick.After you have filled in the water to desired setting normally 1 bar stop the valve.You will notice the valve will get stuck once more if you try to open the valve again.Make sure you bleed the tank in the boiler before you wind the valve, if not the pressure will drop once the air is bleede afterwards and you will be repeating the whole process again.Get a new valve and replace its very simple.
Hope this helps you, good luck.