Ok it's fixed now.
The problem just incase someone else has something similar.
The valve which is attached to the air tank on top os the safety pressure release valve. This is opened by an airline (8mm dia) from a pressure sensor in the air line from the compressor. What seems to have happened is that the valve was opened as normal when the pressure went above 10 bar. BUT the valve failed to close afterwards.
Having removed the valve from the tank it was clearly in the open position (able to blow through it). Basicly the valve was just sticking. I was able to seat the valve and it sealed ok. So i lubricated the vavle with light oil and cleaned the whole thing up, years of road debris must have taken their tole.
Refitted it and it all seems to work fine.
Lorry stranded for 3 days but hey fixed now.
If anyone wants a service manual for an IVECO Tector 6 to 26t i belive its 2003 onwards but it will helped me work stuff out on mine anyway. I have the PDF its 300 odd MB, no elecrtrical setcion tho. Happy to stick it up on Rapidshare
I Need a Iveco Manual for 1996 75E15 anyone got one.