Recent: Will I need to replace my garden tap?

Mend > Oil Filled Radiators

Mend Worcester Bosch Danesmoor 15/19 Heating Radiator

Worcester Bosch Danesmoor 15/19 ran out of oil?

I ran outof oil recently. Once the tank was filled. I opened the pipe to the injector to bleed and the system fired up and runs. BUT When the system is not running for a couple of hours it will not start and the 'Lockout' light comes on and I have to open the pipe again to start. Am I bleeding the styetem properly?Any ideas

Paul
April 2008
Sounds like where you have disconnected the pipe to bleed the air, when the burner is not running there is a slight ingress of air through this join, which would allow the oil to drop back to the tank (assuming the tank is lower than the burner)

If so, fit a tiger loop to the system to stop this happening in the future.

T
April 2008

Related Questions ...

Mend heating boiler pipework
2

worcester bosch 240?

my boiler was drained from the small tap underneath the boiler while we had a new radiator and pipe work fitte... [Read more]
Mend heating boiler pressure
1

getting preasure back up in my worster bosh combi boiler?

i blead the radiator in my living room now i hav no heating or hot water how do i get my preasure bk up ? x
Mend boiler radiator heating
1

heating on all the time ?

hi i have a woscester greenstar ri that wont switch off ie when boiler in timed mode the heating is still on w... [Read more]
Mend boiler radiators heating
2

My radiators on the first floor do not work until I run some hot water?

We have a problem with our Worcester Bosch “Heatslave 26/32 RS0 GB oil Combi” boiler, which provides hot w... [Read more]
Mend boiler pressure Worcester Bosch
2

WB Greenstar 28i Pressure Problems?

My Greenstar 28i has been running for about 32 months and has been serviced annually. I have noticed that whe... [Read more]
Mend heating frost protection
1

frost precations?

If I leave my boiler on and my radiator valve thermostats set at frost setting how reliable is this to protect... [Read more]
Mend combi boiler heating pressure drop
1

how can i fix my worcester combi 350 boiler?

When heating is running, its ok radiators stay hot. When heating is off, pressure drops to zero. seems to happ... [Read more]
Mend combi boiler heating repair
2

How can I fix problem with Worcester Bosch 24CDi Combi?

I have just had a kitchen re-fit and the workmen took the radiator off to plaster. I now have had to turn the ... [Read more]
Mend combi boiler heating worcester bosch
18

Worcester Bosch 24CDi Combi - occasional hot water?

My boiler has worked fine since being fitted by BG in 99. Serviced annually. Last week it stopped continuall... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Oil Filled Radiators ...