Recent: Fix food processor motor?

Mend 105E Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Click here to mend 105E home heating systems

Mend > Home Heating Systems

Mend 105E Water Needed Max

my 105e keeps takeing in water and presure is building up to limit?

what part is needed? my 105e keeps riseing to its max presure i have to run it down 2x a day i know it is not passing through loop filler as it is disconected it also drips water from the air screw on the pump???

john mccann
November 2007
if it happens when your heating is on it may be that there is a problem with the diaphram in the expansion vessel ...if it happens when the heating isnt on it will most probably be the plate heat exchanger has a small hole allowing the cold water in to pass into the primary circuit and will need a new plate

brandon
December 2007
Is the pressure rising when the boiler is on or does it do this when its stone cold and hasnt been used?

Mr A
November 2007

Automatic Answer

We may have found other answers which could help you.

Click here for Water Needed Max

Mend Heating, Home Heating Systems
Click here to mend 105E home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Click here to mend 105E home heating systems