Rotating the large control wheel should open and shut the blade valve to the cassette. To flush the unit you should press this control wheel downwards. It may have got stuck down if something has fallen on the contol wheel so try gently pulling it back up. If this doesn't work you will have to remove the cassette and locate the microswitch which is at the bottom of the control wheel assembly.
Dave