problem . the machine trips the house fusing , water on the foor ,
no water finding its way to the collection box,
condensing water collection design fault , (water on the floor )
this will be of use to people who have one of these machines for around 12 months ,
the machine has worked well for up until this week when water was noticed at the front of the machine ,and then a day or so
I found that water was building up in the pressed steel cover which houses the heaters on the rear of the machine,remove the cover and dry out with a hair dryer and then replace , and that was the season for the electrical trip cutting off , but the reason that the water was getting in there was in the pump enclosure which is next to heater enclosure cover it is a grey plastic box with two tabs at the bottom left corner of the rear of the machine if you pull the tabs to open the cover and then pull up the water pump you will proberly find the the water in there has fluff in it which you need to remove and then check that at the rear of the box left hand corner that the hole at the bottom is clear , it will proberly be blocked poke it clear and flush it out a few times , by removing the heat exchanger
from the front of the machine and look to the back of that compartment and you will see fluff on the back wall water drains from into the pump box , tip some clean water into it and clean up any fluff .
when you have done all that put the pump box back together . you can check all is well and the pump now sending the water back into the water collection box at the top of the machine by removing the black pump hose from the collection box and put the tube into a bottle , you can add some more water into the machine via the heat exchanger port at the very back or wait for some clothes to dry in the machine.
I hope this helps . Robb Barrett
.
Robb Barrett
February 2008