Recent: Home max fs506x?

Mend > Home Heating Systems

Mend Ravenheat CSI 85T Boiler PCB

ravenheat csi 85t?

my problem started two & a half years into its life somtimes the boiler would not fire up on program or manually some times it would start up ok, on program startup you can hear cklicking sounds as if its going through the motions. called out the gas fitter who fitted it and he says its the main pcb control board that needs replacing does anybody know if this is correct at the moment the bolier is working but you dont know when its going to stop

anthony kershaw
April 2007
I believe I had a similar type of problem with the same boiler type but mine would not light without continually resetting the switch over and over again. The process would commence on either cycle but the boiled would trip out and the red light would come on. I tried all the usual suggestions (no small expense !!) until I finally decided that I seriously needed to understand how the thing works. What I discovered was that the fan, although it was working, it wasn't rotating fast enough when cold to increase the air pressure within the chamber, this acts like a sealed unit with the steel cover in place, and trips the air pressure switch (top right) which turns on the gas and lights the boiler. I found I could demonstrate this by removing the rubber tube from the flue ring (inside top centre), turning on the boiler, blowing gently into the tube and the boiler would light every time, as soon as you stop blowing the flame ignition stops. The cure was simple and cheap, I got my trusty tin of 3-in-one oil from the garage, turned off the power to the boiler and oiled the shaft of the fan in-situ, I found that a bendy straw fitted snuggly over the spout of the oil can and gave me good access to the fan shaft, do not flood it though, a little oil goes along way. I then ran the boiler without lighting it to let the oil do its work. Fingers crossed, the fan now whizzes round and the boiler lights when it should. I can only conclude that initially, by continually resetting the boiler the fan shaft must have warmed up sufficiently to spin fast enough to operate the pressure switch. Might sound crazy, but it worked for me and the tin of oil is cheaper than all those uneccessary replacement parts I ended up buying. Hope this helps.

David from Watford
April 2007

Automatic Answer

We may have found other answers which could help you.

Click here for Boiler PCB Ravenheat

Related Questions ...

Mend ravenheat white boiler
2

What is wrong with my ravenheat white star combination boiler,?

I have a ravenheat white star combination boiler,it suddenly decided not to turn off,its on all the time,I hav... [Read more]
Mend ravenheat pcb central heating
1

my ravenheat rsf 84 et boiler?

can someone help me my reavenheat rsf 84 et boiler when you turn on the hot water the boiler fires up ok then ... [Read more]
Mend combi boiler lockout pcb
1

intermittant fault on ravenheat csi85at?

on this combi when switched to hot water only boiler does not fire at all.on winter /summer boiler fires on ho... [Read more]
Mend easy replace boiler
2

how easy is it to replace a pcb on a ravenheat boiler, if i take photos ?

If i take photos of the board beforehand surely i just copy the bits that go wherever and heypresto! No?
Mend boiler pressure heat exchanger
1

my ravenheat csi 85t boiler, has an internal leak?

My ravenheat csi 85t boiler developed a leak from the condensing heat exchanger, at the pipe washer.This was v... [Read more]
Mend combi boiler pcb no hot water
3

HELP!!! Ravenheat csi 85 combi?

Heating but no hot water. Turned hot tap on and plunger on diverter valve pushes onto the Micro switch which o... [Read more]
Mend ravenheat boiler repair
3

replacing a pcb ?

How come on this Ravenheat website it states British Gas quotes 'service for your Ravenheat boiler from Britis... [Read more]
Mend boiler heating ignition pcb
3

Ravenheat CSI 85AT fires up and goes of every 20 seconds?

I have a Ravenheat CSI 85at that is just over 3 years old. This is the one that does NOT have the honeywell ga... [Read more]
Mend ravenheat boiler pcb
2

ravenheat csi85at fuse blowing on board?

my ravenheat boiler has developed a problem. the main fuse on the pcb keeps blowing. it blows when the boiler ... [Read more]
Mend ravenheat pcb heating
1

how to fix ravenheat csi primary A boiler?

came off holls boiler stopped working replaced PCB,still not working,comes on for 30 secs then goes out,starts... [Read more]
Mend heat fault find
1

ravenheat rsf100et no hot water or heat?

i came to fault find on this boiler, pump runs, fan runs, pressure switch ok boiler lights on pilot light and ... [Read more]
Mend ravenheat pcb heating
1

Ravenheat Silver Star LS 80?

The boiler fails to start with heating or domestic hot water. There is 230v into the control panel through th... [Read more]
Mend boiler central heating PCB
1

Ravenheat CSI 85AT Boiler. Central Heating not working?

After switching the setting on my Ravenheat CSI 85AT Boiler to Central Heating and Hot Water (its been set to ... [Read more]
Mend combi central heating ravenheat
8

Ravenheat CSI 85T?

Hello, I've had a good look around this site and can't find an identical issue, so I'm hoping someone can h... [Read more]
Mend boiler heating replaced
5

Ravenheat RSF84ET combi boiler, what's wrong with it??

Hi, no heating or h.w. Corgi plumber replaced 'gasvalve pcb' and 'main pcb' yesterday, got it working, but it ... [Read more]