Recent: Home max fs506x?

Mend > Home Alarm Systems

Mend Scantronic 9651 Problem Alarm Happened

What is the problem with Scantronic 9651 burglar alarm?

Sorry if this is vague but I do not understand what has happened to my burglar alarm and find it hard to explain, but I will try to explain as best I can.

This morning the alarm started going off randomly we worked out it seems to the sensor in sitting room that is the problem because when we cover it the alarm stops, however the keypad shows a triangle with exclamation mark in orange lit up,
also before we covered the sitting room sensor the keypad said "call an engineer"
Is there a way to correct this without calling an engineer, and if we do have to call a one how much on average can we expect to pay? (live in Gateshead area), we are pensioner's and don't want to pay out if we can fix it easily.

I Wilkinson
February 2016
gts
Thanks I need to ask you
When key in the 07890 number again to get into the installers mode
You say "open up the end station,find the tt section on the pcb fit a link across the terminals" , how do we get to open up the "end station" also what is the TT scection, also what is the pcb?

Im sorry if this is tedious for you I understand, if you think this might be beyond us because as I said we reall have no clue as to what we are looking at it all seems double dutch to us please just say if you think we should just call in someone to fix this?
Once again thanks for the time you have spent already.

i wilkinson
February 2016
its a global tamper on this unit check the pirs cases that they are properly closed,next check for cut cables,have you had any new carpets fitted? if you cant find the fault then key in the 07890 number again get the installers mode up again,open up the end station,find the tt section on the pcb fit a link across the terminals,(short it out ) not ideal but will get your system back up and running,then close cover key in 99 enter it will ask you if you want to leave engineering say yes then all should be good ,let me know please if this helps

gts
February 2016
gts or any other kind person

I found out online if I key in 99 I can get out of installer mode BUT I now have message "ZONE TAMPER 201, the 201 changes to 201,202,203 constantly.
Any ideas please?

I Wilkinson
February 2016
gts
Sorry to be so long answering had other more important problems.
We tried entering 07890 and that stopped the sensor going off, however on the alarm display we have "Installer mode" if we press the tick it still displays "Installer mode" can you advise me how I should proceed please?

I Wilkinson
February 2016
a pir is the beam that u have covered up ,its an infra red detector ,in trade a pir 07890 is the factory engineer code ,we change it to our own when we install the system some electricians who are not alarm engineers and dont have to follow the rules we do dont bother to change the code ,try it and see ,if it works it will ask you if you want to leave the engineer menu just say yes

gts
February 2016
Thanks gts
The company who installed it has stopped trading now, we don't even know what a PIR is. Is the 07890 to reset to default?

I Wilkinson
February 2016
Thanks for reply, not sorted yet though.

I Wilkinson
February 2016
you may have a faulty pir or a spider in it if the panel has been prog for engineer reset then you will need call the company who installed it to key in his engineer code,or,get another company who will reset the panel back to factory settings if you remove the cover of the sensor you will cause a tamper that will require the engineering code to reset the panel,you could try 07890 c if that works

gts
February 2016
This may halpo a little.


http://www.diynot.com/diy/threads/scantronic-9651-how-to-find-each-zone.231219/


Do more searching for - say - "scantronic 9651 sensor spurious"

XXX
February 2016

Related Questions ...

Mend scantronic keypad battery
2

Scantronic 9800 problem?

Hi, this morning I unset my alarm (28 years old) and as I am doing some electrical work in the kitchen, I need... [Read more]
Mend optima 2 alarm
1

How can I fix my optima 2 alarm?

I have an optima 2 plus alarm the main box is upstairs with a keypad downstairs. The power red light is flashi... [Read more]
Mend security system panel
2

alarm activating when code put in showing sterling tamper?

I have a sterling 10 alarm system that has been working up untill this morning it was installed in 2006.When i... [Read more]
Mend security home system
1

How do I prevent my Optima Plus alarm system going off!?

Twice in the past week my Optima Plus Home Alarm system has gone off in the middle of the night & I have been ... [Read more]
Mend alarm power happened
7

Optima 2 plus home alarm?

Please could someone help with my home alarm problem. When we have a power cut at home this causes the alarm t... [Read more]
Mend alarm alarm system manual alarm
1

problem with my optima 2 plus home alarm?

Please could someone help with my home alarm problem. When we have a power cut at home this causes the alarm t... [Read more]
Mend security system reset
2

how to switch the veritas alarm off?

my alarm went off twice today.Everytime we entered the code and then pressed "reset" button to switch it off.I... [Read more]
Mend security system fault
1

Veritas 8 Alarm sounds wen the system is not in use?

In October 2008 I had a Veritas 8 Alarm system installed by and alarm company which has since ceased trading. ... [Read more]
Mend open hello help morning
3

Scantronic 9800 shows a zone as open but it isn't?

Hello and asking if someone can help. Yesterday morning was able to set the alarm as usual. Later in the da... [Read more]
Mend security system alarm optima xm
1

Same as Vivian Conway on Optima XM?

My question is very similar to Vivian Conway March 2008 after turning off all power to instal new points my al... [Read more]
Mend alarm system zones
1

my optima xm alarm system is not working, all?

my Ade Accenta compact alarm system is not working, all zones are lit up, plus the tamper light is on, i tried... [Read more]
Mend optima alarm working
2

optima xm alarm system not working after power cut?

after a power cut in my area my optima xm alarm system is not working, all zones are lit up, plus the tamper l... [Read more]
Mend accenta g3 panel
3

Tamper Activation on Accenta G3?

I have an Accenta G3 panel c/w remote keypad. Every few days the panel is going into alarm mode and when reset... [Read more]
Mend security system alarm
3

Why does my Optima XM alarm's internal bell keep going off?

Wondered if anyone could advise. Last year my Optima XM alarm started playing up. The internal alarm kept goin... [Read more]
Mend remove optima alarm
2

How can I remove a tamper lockout on my Optima XM6 keypad ?

Over recent years our alarm has sounded whenever mains power is restored after a powercut. Although a bit of a... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Alarm Systems ...

Related Categories

Mend Car Alarm Systems
Car Alarm Systems