I don't know if it's plasma or lcd, but this code works for both.
count how many times the green light flashes before it shuts down'find error code below.
1 Blink SOS: This shutdown operation is usually caused by a lack of communication between the A and the D boards.
1 Blink SOS: This shutdown operation may be caused by the improper connection of a SS board connector to the panel.
2 Blinks SOS: Pin 87 of the MPU IC9003 monitors the 15V line. During normal operation, the transistors Q9053 and Q9054 output a high to pin 87. If the 15V line is missing or shorted, a low is provided to pin 87. As a result, the unit shuts down and the power LED blinks 2 times.
3 Blinks SOS: IC9807 is a 3.3V regulator located on the D board. Its output is monitored by IC9003. If the 3.3V is not present at pin 86, the MPU shuts down the unit. The power LED blinks 3 times.
5 Blinks SOS: Pin 85 of the MPU IC9003 monitors the 5V line. During normal operation, the transistors Q9051 and Q9052 output a high to pin 85. If the 5V line is missing or shorted, a low is provided to pin 85. As a result, the unit shuts down and the power LED blinks 5 times.
6 Blinks SOS: Pin 90 of the MPU IC9003 monitors the status of the SC board. During normal operation, the transistor Q6581 and IC6581 output a low to pin 90. If the SC board becomes defective, a high is provided to pin 90. As a result, the unit shuts down and the power LED blinks 6
6 Blinks SOS: 6 blinks of the power LED may also be obtained from pin 3 of IC9003, the DRV_RESET input. The D board provides the 5V source needed to power the C boards. On the C2 board, the 5V is routed back to the D board via connector C20/C10, C11/D31 causing pin 3 of IC9003 to be high. If 5V is not routed back to the D board, pin 3 of IC9003 goes low. The set goes into shutdown mode and the power LED emits 6 blinks.
7 Blinks SOS: Pin 93 of the MPU IC9003 monitors the status of the SC, SU, SD board. During normal operation, the photo-coupler PC6480 outputs a low to pin 93. If the SC, SU, or SD board becomes defective, a high is provided to pin 93. As a result, the unit shuts down and the power LED blinks 7 times.
8 Blinks SOS: Pin 91 of the MPU IC9003 monitors the status of the SS board. During normal operation, pin 8 of connector SS23 outputs a low to pin 91. If the SS board becomes defective, a high is provided to pin 91. As a result, the unit shuts down and the power LED blinks 8 times.
10 Blinks SOS: The SUB5V and DT9V sources created on the A board are monitored by IC1100. If they are not present at pin 30 and 34, the MPU shuts down the unit. The power LED blinks 10 times.
10 Blinks SOS: The F_STB_15V of the P board, as well as the derived SUB5V and DT9V sources are monitored on the A board for excessive current. If a short circuit is developed in one of the supplied lines, pin 114 of IC1100 receives a high. The SUB5V and DT9V lines are also monitored for excessive voltage. When an over-voltage condition is detected, a high is also output to pin 114 of IC1100. The DT9V is provided to a DC/DC converter to create the BT30V for the tuner. If the BT30V becomes excessive, a high is output to pin 114 of IC1100. A high at pin 114 of IC1100 causes the unit to shutdown and the power LED to blink 10 times.
Good luck.
flyatyou66
July 2014