check wall thermstat batteries this caused my f23 code
peter thomas
November 2021
Vaillant eco tec plus How can I get a F23 fault code when I am not using central heating ?
I have cleaned the heat exchanger (not very dirty) changed both sensors (on the exchanger and hot water flow)
the original fault was the pressure vessel was full of water, so changed it. I have a good flow rate and the pump works fine . BUT my hot water goes from hot , to cold, to hot , to cold then nothing but F23 fault
arthur
June 2016
Water temprature difference between flow and return ntcs too large.
Possible causes are:
Water pressure too low:
Pump running too slowly:
Faulty flow or return ntc:
Wiring to ntcs has been reversed:
Carefree
November 2011