Recent: Will I need to replace my garden tap?

Mend > Plumbing

Mend Radiators Plumbing Heating

drained radiators?

drained radiators to disconnect one and now the radiators and the water will not heat up.

phil
July 2009
pete w, i guess u are not a plumber as you're info is wrong, when u bleed a heating system always start at the ground floor not the highest rad, put the pressure up2 about 1.5 bar & bleed the rads topping up the pressure as necessary don't 4get that the final pressure should be about 1 bar when cold, if u take the pressure above 3 bar the pressure relief valve will open & once they do that they tend to leak

Keith Gillyon Plumbing, Heating & Building Services. Southampton.
August 2009
phil did you bleed them all after repairing, turn heating on and get a bleed key from hardware and start on any rad but bleed them all twice airlocks move.
To be sure this is prob turn heating on now and give it 10mins then feel both pipes feeding the rads (bottom left and right) you should find heat in one side.

ciaran
July 2009
Hi,
Nornily just air in the system try the following.

1/ Take the boiler preasure up to about 2-21/2 bar (tiurn off power to boiler as you do not want it to start.

2/ start at the highest Rad and vent it.

3/ Work your way though ALL the Rads.

4/ Make sure that the boiler presure does not fall belew 2 bar but not above 3 1/2

Hope this helps.

Pete W
July 2009

Related Questions ...

Mend oil pressure heating tank
2

myson velaire oil fired pressure jet boiler 70/90?

Hi there, I am currently re plumbing my central heating system which had a leak somewhere which is currently g... [Read more]
Mend heating pressure thermostat
1

Ideal Icos Boiler, Heatrae Sadia CL170, Reliance Pressure gauge?

My CH/HW system consists of the above components plus a room thermostat and control panel beside the boiler. A... [Read more]
Mend How to mend it?
3

WHY HAVE 2 BRAND NEW AARROW STRATFORD TF90 MULTI FUEL BOILER BUCKLED?

I bought an AARROW STRATFORD T90 80,000btu got company to fit and after only 6 weeks it buckled all round the ... [Read more]
Mend heating thermostat gas valve
10

Potterton 16/22 - won't light?

Hi there, Yes it's an old boiler, but there's not money to change it or even call anyone out. I'm on the ve... [Read more]
Mend heating plumbing radiators
1

plumbing and heating?

vaillant turbo max plus boiler when hot tap is on the radiators come hot and the water out off the tap goes ... [Read more]
Mend burner glow worm
1

Glow worm micron 50ff boilerstat?

Hi, I have a Micron 50 ff which seems to work perfectly in that the burner comes on when required and heats wa... [Read more]
Mend out central heating system
1

How do I flush sediment out of my central heating system?

I have a central heating system with 11 radiators. Sediment in the system is reducing efficiency and I have be... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Plumbing ...