Recent: Trying to find lawn mower part- Power Devil PDG4037R?

Mend Remeha Avanta Plus Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Find out how to mend Remeha Avanta Plus home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

Remeha Avanta Plus 28c - Advice Please!?

Hi, my wife told me the boiler wasnt working today so I had a look and saw there was no pressure in it! And it was displaying error code E5. I have filled it up to 1.5bar and reset the boiler. It will only go so far through its start-up checks and then says E5. I looked in the peep-hole inside the boiler and can see it is lighting ok.

In the user manual it says the following:

Error Code - E5

Description - No ionisation or ionisation failure more than 5 times during one heat demand.

Possible cause - CO2 wrongly adjusted

Check / solution -
Check:
• CO2 adjustment on the gas block;
• ignition/ionisation pin;
• flue/air-supply connections;
• gas flow at full load;
• if there is no recirculation of flue gasses (either inside or outside the boiler).

I dont know if the low (no) pressure is the cause of the error or the result of it, or neither.

Can anyone tell me what/how I should check? Does this sound like a big problem or a simple fix?

Many thanks in advance!

MyName01
July 2009
Just to update you, the fault was due to faulty controller board. A replacement circuit board cured the problem of E13 error. Engineer serviced the boiler to change burner seals and normal cleaning in and out side of burner at the same time.

diamondpack
June 2017
Hi All,
Guys I am seeking advice to order the correct part to cure the error code E13 with Remeha Avanta Plus boiler. Boiler works fine for central heating side of the system but if we turn the H water then error appear on the display.
I reset the error then boiler work for few minutes to give really burning hot water and then kick the E13 again. The behavior of the boiler really either due to the plate heat exchanger issue or control board has voltage path that control the control the heat sensor need attention. After close inspection of the control board, I can see a swollen capacitor in power supply part of the board.
Any one engineer comes across with identical problem and what was the cure for the fault? Can you please help, will appreciate your input.

diamondpack
May 2017
I have the same problem. We changed electrode, gasket, gas valve. Now technical team saying need to change transformer. After that will be something else i am sure. Most rubbish boiler ever Remeha Avanta plus 28c. So many parts related to one error code e5.

Kristina
January 2016
I have had the E6 error repeatedly on my 24c - BAXI changed the pcb but E6 has returned within one week any ideas?

Grumpy
March 2015
39c flow pipe gets hot when d h w water is on I have changed the 3 way iner valve but no luck same thing happens

Sam
March 2015
If the people giving information out regarding gas boiler repairs, are gas safe registered engineers, they need locking up. Why do you think we pay for outrageously expensive gas courses, to keep our registration up to date. Its not to give out information to people who are not qualified to carry out gas work, who can cause a danger not only to themselves but other people too.

Brian Clark. B. clark & Son
February 2015
Get rid and buy a proper boiler one that works we just did and it's the best thing we ever did remeha are rubbish

Terry
May 2014
Maybe I had a bad one but unreliable over the 5 yrs life to date. Dozens of E4/E5 faults, most components changed by Gas Safe fitter - probe 3 times, transformer, PCB. I will never buy another product from Remeha.

Snoopy
January 2014
Buy an ideal logic plus...best boiler on the market.

iplumb.com
October 2013
I take it your gas engineer checked the inlet working pressure to the boiler which should be as near as possible 20mb. The vibration tends to occur through poor combustion which generally is down to working pressure or incorrect air gas ratio adjustment..DO NOT attempt to adjust the gas valve without the correct equipment, it could prove to be very dangerous. I would also get the pipe sizing checked ad the meter governor, also make sure the ecv is fully open

chris m
October 2013
mike beaver - my boiler also making a noise when firing up sounds like the whole thing will vibrate off the wall, Gas engineer thought it was the gas valve - had this changed, was quiet for a few hours and now back to the vibration again - any engineers on here that know what is causing this? remeha direct have no idea.

nic
October 2013
Those of you even attempting to repair your own boiler are BREAKING THE LAW! Call a gas safe registered engineer, keep yourself and your family safe.
Remeha boilers are excellent boilers, easy to repair and service IF you are qualified. All Avantas used to come with a minimum of 5 yrs parts and 2 yrs labour warranty so you shouldn't need to attempt to repair it yourself anyway.

Those of you on here who are gas safe registered and are giving repair advice should be ashamed of yourselves, all it takes is for someone to incorrectly refit a part or to miss reinstalling a seal for a potential disaster to happen.

Ackroyd Plumbing and Heating Ltd.
April 2013
my water pressure is goes low every day and i have to keep topping it up for then radiators to get hot, i never used to have to do this every day, does anyone know whats wrong with it???

ian
February 2013
I have been having E5 failures , I can reset it and it goes for a few day then fails again. The odd time it showed E6 . I firstly re soldered the PCB some bright spark decided to use lead free solder how stupid being in an envoirment hot and cold joints will crack. This should only be done if your up to it. It did not fix the problem but its needed to be done. I then fitted a service kit (main burner seal and ignition electrode ) fixed problem so it was one of two items. All of this work must be done by a CORGI Reg Person

Mr Smith
January 2013
Hi got a Remeha making a noise like a jet engine when it fires up any suggestions ?

Mike beaver
December 2012
Hi guys been working on remeha boilers for about 6 months now and e5 fault code comes up a lot so try changing electrodes and transformer unit (the one that's at the side of the gas valve ) seems to sort it every time. E6 can be a pain but technical say pcb fault which to be fair does clear the fault code and not had one come back at me as yet. Hope this helps!!

Wakaday
October 2012
Hi, I do repair boilers every day, but never met a boiler so difficult to fix like Remeha Avanta Plus range. Anyway - from my experience to solve E10 fult means that you need to keep open all rad valves after you switch off boiler from mains and made sure one rad is kept open allways. Of course it should be full of water 1 bar and make sure the air got out of boiler and pump. I`m still looking the solution for E5 unfortunately, so as soon as I find it out I will post it. But if you`re a landlord - very expensive and very difficult to fix the problems. The new PCB costs £232 - when E6 appears!!! Hope the above info will help someone.

Ross
November 2011
Isolate the power to the boiler and remove outer casing. Unscrew the 2 philips screws holding the ionisation probe unit(careful not to nip the red insulation cover) and remove from heat exchanger. Clean the probes with wire wool(emery will suffice but be gentle). When nice, clean and shiney, put it all back together. Switch power to boiler to on, press "R" and that should do the trick. Getting an E.5 error could also be a good time to get your boiler serviced.

Corgi Paul
March 2011
The first digits are 07.

Ian Weatherhead
January 2011
I have error code E10 displayed on my boiler.
What does this mean and how is it repaired?

Ian Weatherhead
January 2011
Dont start messing with the gas valve!

Mr Boiler
August 2009
how old is the boiler you can tell with the first two digits of the serial No. ie:08.If its still in warranty then book a call direct with the company and it will be sorted same day/next day.

Help
July 2009

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Advice Working Today

Mend Heating, Home Heating Systems
Find out how to mend Remeha Avanta Plus home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Find out how to mend Remeha Avanta Plus home heating systems