Potterton Suprima keeps cutting out?

We have a Potterton Suprima 40 which keeps cutting out. We have to keep pressing the flashing red reset button and it works again. It goes through stages of doing this, sometimes not for weekes, then several times in one day. Could it be because I cover the radiators with washing sometimes? It's doing it at the moment and I have washing on the rads. Thank you

Rachel
April 2009
Quite right PCB's on these boilers featured on BBC Watchdog! The PCB now is a compete upgrade compete with wiring loom and control tray, will take a Qualified guy around 3/4 - 1 hour to do cost approx £195-00 + Fitting & Vat

BUT. Before goinig for this, it is worth checking the working Flow & Return temperatures to make sure the thermistor (£10-00) is OK and that there is adequate flow around system, (11'c Temp rise across Boiler)
I have also found on occasions this fault is caused by an intermittant fault in the Gas control Valve (£150-00)

You should ge a Gas Safe Register Listed Engineer holding CCN1 &CEN1 Qualifications to investigate and repair

I am pleased to say that the current PCB's for these boilers seem to work reliably and to date we have had none fail in about 2 years of use

Boiler Repairman - Ipswich
April 2009
Its got nothing to do with putting your washing on the rads, these boilers are well are well known for PCB playin up on them and i'm pretty sure the PCB's have been upgraded now

STE
April 2009

Automatic Answer

We may have found other answers which could help you.

Click here for Potterton Heating System Reset Button

Related Questions ...

Mend boiler potterton heating
1

How to resolve potterton performa 24 no HOT WATER issue?

Hi Guys, I have potterton perfoma 24 Boiler. I do not get hot water once i open the hot water TAP either it... [Read more]
Mend central heating potterton pcb
1

Flashing green LED on Potterton Suprima 50?

Central heating stopped working last night. Tried resetting unsuccessfully. When reset button pressed the pum... [Read more]
Mend Potterton EP2001 Central Heating
3

how can i fix my EP2001 programmer?

drained central heating to add new rad, didn't turn off electric to programmer and now it doesn't work. Had a... [Read more]
Mend central heating gas fire back boiler
2

How to stop Potterton Back Boiler going to Lock Out?

Hi I moved into my present house several years ago and found that the central heating system is provided b... [Read more]
Mend boiler pcb lockout
14

Potterton Suprima Boiler Won't start?

I have a Potterton Suprima 30 in a five years old house. Last year the PCB had to be replaced due to the syst... [Read more]
Mend boiler potterton locked out
3

Potterton Suprima 30 Boiler problem?

Recently moved into a house that has a Potterton Suprima 30 boiler, house is about 10 years old. When i fir... [Read more]
Mend boiler central heating sludge
1

Potterton Profile 30E keeps tripping on Central Heating?

My Potterton Profile 30E keeps tripping off and requires the reset button to be pressed to restart. This typic... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...