My Sharp Carosel Model R-5A98 blows its internal 20 amp fuse. Any idea?

There must be a problem with the magnetron or its modulator. Can it be fixed or replaced?

John Bjornholt
November 2005
If the fuse blows as soon as you plug the oven in the wall, or when you open the door, the problem is likely with the door switches.

If the fuse blows as soon as you hit START, then it's likely that you have a shorted high-voltage capacitor.

If the fuse blows a few seconds after you hit START, then it's likely that you have an overheating / shorting high-voltage transformer.

If you or a friend decide to work on it, we have *critical* safety and disassembly info at our site, as well as other specific troubleshooting information and help.

In my professional opinion, people should not work on a microwave unless they are fully informed and aware of the deadly hazards and necessary precautions.

One can find such information and very specific in our safety and disassermbly text files at http://www.microwavedisplay.com

William Miller † MicrowaveDisplay.com
March 2007

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for 20 Amp Fuse

Mend Kitchen Appliances, Microwaves
Click here to mend Sharp microwaves

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Kitchen Appliances, Microwaves
Click here to mend Sharp microwaves