Recent: Windows 11, Dell 5450, JBL Bluetooth headphones?

Mend > Home Heating Systems

Mend Halstead Finest Gold Combi Pressure Lockout

Halstead Finest Gold Combi Boiler water going cold / heating locking out?

The water is only luke warm even though i have turned the temp up and the central heating will start up and run then somtimes lock out with the red light flashing.
I have the pressure gauge on 2 bar and its holding, when you listen to the boiler when its firing it tries to light several times before cutting out
Any ideas

Barry Read
October 2008
my electric has been off and my halstead boiler will give me hot water but can not get the radiators to come on and can not any answers please

scott
May 2015
Hi guys have any of you tried removing the heat exchanger and giving it a clean out. Leave it to soak in some cleaning fulid and the then replace. These get blocked and cause all sorts of problems. Also if you are loosing preasure with no leaks it is more than likely your expansion vessel. You can check the air preasure and prime it up with a bike pump. Also advise flushing your radiator sytem and then when you empty it out top it up with inhibitor fluid to stop the rust and sludge traveling through your boiler. Had a lot of problems with my halstead finest gold boiler and had a lot of engineers telling me I need a new boiler or they dont no what the problem is. It is 12 years old and has only ever had a pressure release valve fitted as a new part. I found my boiler issues were just poor maintance and poor servicing that led my boiler to have a lot of the same problems you guys are having. Hope this helps.

steve
December 2013
hi ive just had one like that, the manual states the over heat stat or thermistors but remove the fan clean it grease it replace it in my case this wasthe answer the manual dosnt mention the fan but halstead engineers do

matt
January 2011
any ideas halstead finest gold combi trips out when hot water on, trips out when c/h on max, but when c/h on min dosnt trip out for 4 hrs
when the over heat thermostat is removed from the pipework the boiler trips out ? any ideas Thanks for any comments Matt

Matt Charnock
January 2011
The problem was the expansion vessel on my Halstead instead of buying an expensive one especially for the Halstead boiler we purchased a bigger 12 L vessel and link directly to the heating and it's now perfect

Ray
December 2010
hello, in search of a control panel for halstead gold finest,appliance number 47.333.13 /ce 0087/bm/37 seril number fx.g 60459.0310

mr james wilson
October 2010
I hope this helps in some way, I had the same probs with mine, i replaced the diverter valve, cleaning the 2 feed pipes aswell as a little calcium had built up in the ends, 2 thermisters/2 flow switches/auto air vent/pcb and igniition leads, and still it did not work, only 1 thing left THE AIR PRESSURE SWITCH which someone mentioned some where on this site, THANKS, ITS NOW WORKING A TREAT, its now like a new boiler with all the new bits added, and it should last a few years more now,

daren
October 2009
I had a similar problem some years ago on a Halstead Finest combi, when I had just bought the house. After my engineer did what he could following calls to Halstead, it was still a problem. I found that there is a little cap on the top of the outer boiler casing that I think blanks a test point for flue gases. It had been left off - refitting it cured the problem.

Keith
January 2009
I have had one of these boilers for seven years and rue the day I purchased a combination boiler. Recent problems have seen expensive repairs for injectors and overflow valve and now random cut light the same as your problem. Engineer states control panel £200+ or gas valves £150+ but no gaurantee on either will work. Is there such a thing as an efficient combi boiler as unfortunately my house layout and cost forbids the fitting of a conventional system?

Very Frustrated, Derbyshire
November 2008
I had a similar problem a while back - turned out to be the PCB which are quite expensive.
However give the Halstead service line a ring they are usually very helpful as the fault could be one of a couple of things. The number I have is 01926 834834.

Paul
November 2008
Hi Barry,
Mine is doing exactly the same, saw your question as I was searching! Let me know if you find the answer please. Ive serviced it and Im thinking about changing the changing the thermister on the dhw. Good luck,

Nino

Nino
October 2008

Related Questions ...

Mend combi heating lockout
2

lockout light still on after filling pressure on combi?

I filled my boiler after it went into lockdown after loosing pressure, yet it still wont work. No heat and no ... [Read more]
Mend boiler error code water pressure
5

Morco FEB-24ED Supercompact boiler?

I have a static caravan and the combi is showing an error - F3 which is a lockout for reduced water pressure (... [Read more]
Mend combi boiler lockout pcb
1

intermittant fault on ravenheat csi85at?

on this combi when switched to hot water only boiler does not fire at all.on winter /summer boiler fires on ho... [Read more]
Mend combi boiler heating hot water
2

My Halstead combi boiler refuses to work any more - help please!!?

Hi, I have a 6yr old Halstead Ace High combi boiler which has never given me any problems until now. About 3 -... [Read more]
Mend boiler heating lockout
2

how can i fix my ferroli modena 80e combi ?

I recenntly had a new fan fitted on my ferroli modena 80e and now whenever it rains water gets in to the fan a... [Read more]
Mend boiler combi worcester
1

Worcester Bosch combi boiler 24Si II - hot water from taps but not shower!?

Hi Please can anyone suggest a solution to the following: My hot water seems to be ok - radiators come on... [Read more]
Mend boiler pressure lockout
1

Biasi Combi Boiler not working, help!?

Hi I wonder if some kind fellow could help me with a problem I have with my boiler Firstly appologies as I ... [Read more]
Mend combi fine system
1

combi lockout?

i have a chaffoteuex combi boiler which works fine for a while then keeps going onto lockout and i have to kee... [Read more]
Mend boiler heating lockout
6

My Baxi 100/2 HE boiler fires up for 20 -30 mins the cuts out on lockout?

My Baxi 100/2 HE boiler fires up for 20 -30 mins then cuts out on lockout. It started intermittently, hot wate... [Read more]
Mend boiler heating worcester
3

worcester 28cdi problem?

our worcester 28cdi combi boiler will not egnite.system pressure was down to 1 bar,opened both valves,now up t... [Read more]
Mend central heating combi boiler
1

no central heating but hot water working fine?

hi i have a saunier duval 30 e combi boiler.my hot water is fine but my central heating isnt working .there is... [Read more]
Mend combi boiler heating water pressure
1

How can I fix my boiler?

The lockout light cuts in after 5 seconds when I turn the Combi boiler on to either setting. I have tried th... [Read more]
Mend boiler lockout reset
1

potterton combi 80 boiler lockout on?

I have mislaid service manual, aand my engineer can't find the answer to why the boiler continually goes to re... [Read more]
Mend combi leakage pressure
1

potterton puma combi boiler ,lockout red light comes on,often?

My combi boiler a Potterto Puma 80e works fine but is tempramental.After about 3-4 hrs the lockout red light c... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...