My vaillant 824e only either gives hot water or central heating?
My vaillant 824e combi boiler only gives hot water or central heating. If I am wanting hot water I have to switch the boiler off to get it if the heating has been on, additionally the radiators become hot downstairs even when the heating is supposedly off !!. I have been advised it could be the diaphragm. Any Ideas ?
common fault with vaillant just get the divertor valve replaced. and enjoy the hot water when you need it without having to switch off your boiler. totally agree with other guys
universal heating ltd
October 2008
steve it certainly is the diaghfram in the diverter valve the only cure is to replace the diaghfram or the complete valve assembly.im afraid that it is a very common fault on most combi type boilers and it can be a difficult and expensive job costing around 185 pounds for a proffesional fix.
mr knowitall
October 2008
i agree with the personal bit below VVVV
iain
October 2008
? model
TURBOmax VUW 282 E TURBOmax VUW 242 E
If it is one of these you could try changing diaphragm, personally i would change the diverter valve complete
a
October 2008
I can answer this question...
My vaillant 824e only either gives hot water or central heating?