Hi Has anybody any information/advice on the E1 error code on the Hotpoint Mistral FF72s, I have recently replaced the Evaporator Thermistor and one of the thermal Fuses, following the E8 code. F/F is now working but seems to gathering a little frost in the freezer compartment, also freezer temp does not display, just the E1 code.
where do i find the baffle and how do i check if its working? please
macjean
May 2009
Linz,
Thanks for the information re: error Codes.
Much appreciated
Ray Holt
July 2005
E1 - Freezer thermistor open circuit.
E2 - Freezer thermistor short circuit.
E3 - Fridge thermistor open circuit.
E4 - Fridge thermistor short circuit.
E7 - Evaporator thermistor open circuit.
E8 - Evaporator thermistor short circuit.
E9 - Temperature set switch open circuit
EA - No feedback from Baffle
EB - Fridge Baffle motor operating continuously
EE - Defrost time out