E100 means the laser is not being seen by the laser detection system.
It is very unlikly that the laser has failed. The most likly cause is the shutter. When you take out the drum unit a small plastic finger on the rear of the unit opperates a shutter to cut off the laser when the drum is out of the machine. This finger has probably broken off.
Bob