Potterton Profile 30E keeps tripping on Central Heating?

My Potterton Profile 30E keeps tripping off and requires the reset button to be pressed to restart. This typically happens once a day but can sometimes trip up to 2 or 3 times a day. Heating engineers have looked at the problem and failed to resolve it. At times the room stat will only trip off at 10 degrees even though the room temp is warmer (this was changes 2 years ago). Recently the boiler has had a new pcb, thermostat, gas valve and pump (cheaper to buy a new one probably!!). I also have air rushing round the system which can be heard in the radiators and hot water flowing into the cold water header tank. No amount of bleeding removes the air. The pipework is approx 25 years old and was converted to gas from an oil based system 12 years ago. Could it be sludged, blocked pipes , faulty thermopstat? No idea what is causing any of these problems but any help or advice would be appreciated.

Andy Chiles
November 2006
it could be sludged up try turning pump speed down, also check f/e tank in loft to see if tank is full of silt in the bottom which can cause a blockage in the pipe that feeds the system from bottom of tank. which can also cause your vent pipe to draw in air, also check your boiler stat is on about 3.check your vent pipe by holding a glass of water to it and see if it draws it into the vent pipe.

hi-spec plumbing
November 2006
Mend Heating, Home Heating Systems
Click here to mend Potterton home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Click here to mend Potterton home heating systems