Mend boiler leak heating system
1

do i need replacement part or new boiler?

i have a vaillant combi bolier ref no vuw242 I have had this for about 12 years and now have a leak the water ... [Read more]
Mend boiler stopped water

Problem with Valliant VCW GB 242EH?

My boiler stopped the supply of hot water and heating. Had a plumber out who changed the diaphram and the pump... [Read more]
Mend water pump vaillant
1

how do i stop water leaking from my pump?

hi ,ihave a vaillant turbo max vuw242e,282e,and i have water dripping from the curculating pump when either th... [Read more]
Mend cost boiler water
1

cost of new expansion vessel?

i have a vaillant 828/2e condensing boiler and i have to keep topping up the water level of the boiler too muc... [Read more]
Mend vaillant boiler dripping
1

dripping expansion pipe?

had to renew a leaking diverter valve on a vaillant ecotec boiler, everthing works fine (heating and hot wate... [Read more]
Mend boiler small pipe
2

valliant eco plus 837 boiler ?

hi i have a vaillant eco plus 837 boiler , and recently had a small pipe change for shower head to downst... [Read more]
Mend Vaillant Combi Boiler Water Leak
3

Vaillant ecomax 828/2e combi boiler is leaking water!!!?

I dont have the instruction manual for my boiler but it is leaking from the main big metal bit n the middle of... [Read more]
Mend hot combi boiler
1

vaillant ecotec pro28r, not enough hot water?

hello all, i have vaillant ecotec pro 28r combi boiler, problem is there is not enough hot water but heating i... [Read more]
Mend boiler leak heating
1

VAILLANT VCWGB 242EB COMBICOMPACT BOILER WATER LEAK?

WATER IS LEAKING OUT OF THE TOP OF THE WATER SECTION AROUND THE PLUNGER THAT OPERATES THE MICRO SWITCH WHEN U... [Read more]
Mend vaillant boiler hot

vaillant vuwgb242e boiler?

heating side of it started to hit mian trip out, but hot water was fine. now the hot water is causing it to tr... [Read more]
Mend central heating combi boiler expansion vessel

Vaillant VCWGB242EH GC 4704413 Combi goes out immedi?

Hi, am working on the above boiler, was leaking at the auto air vent so tested the expansion vessel to find it... [Read more]
Mend boiler heating leak
1

Describe Your Heating & Cooling Problem:?

Describe Your Heating & Cooling Problem: leaking pipe to heat exchanger on my valliant ecotec pro24 boiler on... [Read more]
Mend central heating hot water fault
1

vaillant vcw gb 242 eh boiler?

Can you please advise fault on dhw when hot water tap is opened boiler ignites runs for 10 secs then cuts out ... [Read more]
Mend boiler leak vaillant
5

Vaillant TurboMAX plus 824E boiler problem!!!!!?

hi i have had the Vaillant TurboMAX plus 824E boiler for about 2 and a half years, and it seems to be leaking ... [Read more]
Mend boiler showing red light
3

valliant eco tec pro?

my boiler is showing f75 with red light on . no hot water are heating ' what can i do to to repair it , all so... [Read more]
Mend boiler leak plumber
1

vailliant boiler leaking from underneath?

My boiler has been leaking for a while now called out a plumber a couple of months ago and he fixed a new valv... [Read more]
Mend boiler turbomax water
1

Leaking Boiler?

how do i stop my Vaillant Turbomax bolier from leaking? The heating is fine and hot water very hot, hotter tha... [Read more]
Mend boiler heating engineer
2

vaillant 242 eh combi/boiler leaking at the b t m.john?

please can anyone help me the heating engineer told me that my d. h. w.heat exchanger was leaking water also m... [Read more]
Mend boiler heating vaillant
1

Why can't I get hot water for the shower from my Vaillant boiler?

I have a Vaillant turbomax VUW 242E/282E (not sure which) and I just had a re-occurence of a problem in gettin... [Read more]
Mend vaillant vcw gb 242 eh
1

vaillant VCW GB 242 EH?

My dad's VCW GB 242 EH was leaking at diaphram unit so we replaced it and also the divertor. However, the igni... [Read more]