Mend boiler heating hot water
1

Have hot water but no heating?

We've got a potterton suprema boiler and a separate hot water tank. The boiler still fires up to heat the wate... [Read more]
Mend boiler combi hot water
1

hot water problems?

I have a Worcester 240 combi boiler and i can only get warm water (but hot when the heating is on?), i have ch... [Read more]
Mend boiler combination boiler central heating
1

Poor hot water temperature with heating on?

I have a Vaillant Turbomax combination heating boiler. When the central heating is operating & a hot tap is... [Read more]
Mend boiler hot water diverter valve
1

heating problem, whats wrong please?

chaff britony combi 80. hot water fine, heating problem comes on low rate 10 secs then off cycles again when h... [Read more]
Mend boiler pressure vessel central heating
1

Glow Worm Compact 75p pressure build up?

When i turn on my central heating after about 15/20 mins when the system and radiators are hot the pressure ga... [Read more]
Mend vaillant diverter valve central heating
2

Vaillant turbomax combi hot water problem?

just had a new diverter valve fitted as we were getting no hot water. (central heating fine) problem still ... [Read more]
Mend heating 50 boiler
1

Central Heating Problem - Potterton Flamingo 50?

I have a Potterton Flamingo 50 boiler, which caters for the central heating aswell. My radiators upstairs all... [Read more]
Mend boiler heating valve
1

hi how do i turn the heating off but leave water on?

Got regular boiler ,stat is down, programmer hot water switch is on, heat switch is off but heating still come... [Read more]
Mend boiler combi hot water
3

How can I fix my Turbomax 824?

I have a Vaillant Turbomax 824 combi boiler. Recently, when I open the hot water tap without CH on, the water ... [Read more]
Mend diverter valve problem
1

Diverter valve problem?

I've an ICON T combi boiler - no further ID, sorry. Gets CH but no DHW. Help from another forum suggests Diver... [Read more]
Mend worcester boiler years
2

What's wrong with my Worcester 28CDi RSF Boiler?

My boiler is approx. 6 years old and covered by BG Homecare, BUT....... after fitting a thermistor sensor, a m... [Read more]
Mend combi diverter temperature
1

Sime hot water?

Boiler Sime Planet 100e Combi boiler. The hot water delivery varies from hot to cold. The diaphram in the di... [Read more]
Mend central heating burner pcb
3

Glowworm Ultimate 40FF - main burner keeps going out and relighting?

The pilot lights, its continues to spark then the main burner lights then the main burner goes out after a few... [Read more]
Mend boiler heating engineer
2

Glowwork Ultimate 50 boiler - pilot keeps going out?

The pilot light keep going out but immediately relights itself so I am getting hot water and heating. I have h... [Read more]
Mend boiler combi vaillant
4

Combi boiler-pressure low-hot water ok?

Hi, I have a Vaillant Turbomax 242/282e boiler and the pressure has dropped to 0.5. Hot water is fine from al... [Read more]
Mend boiler heating radiators
2

Glow worm ultimate 40ff ultrahot water!!!!!?

Hi, I have the above boiler with potterton ep3002 timer and potterton room stst with hot water cylinder stat ... [Read more]
Mend central heating boiler thermostat
9

Boiler fires up when demand for hot water but doesn't when demand for C/H?

I have a Potterton Netaheat Profile 80e boiler, Honeywell V4073A mid-position valve, Honeywell ST699B programm... [Read more]
Mend boiler radiators glowworm
5

Heating works, but Hot Water doesn't... Glowworm Micron 40FF?

I've having a strange problem at home. If, via the Programmer, I turn the heating on the radiators come on.... [Read more]
Mend motor drum fuse
1

Zanussi FL1084 (Circa 1996 Model.) Blows mains fuse intermittently?

At different points in the wash or rinse cycle I have seen the power lamp flicker and if the machine is left s... [Read more]
Mend boiler home heating gas valve
2

MY TURBOMAX BOILER IS NOT DELIVERING HOT WATER?

THE LED PANEL SAYS FLUE FAN NOT RUNNING,ALTHOUGH YOU CAN HEAR THAT IT IS,THE LED ABOVE SAYS GAS VALVE OPEN BUT... [Read more]