How to mend Boiler Valve Turn Water

Pages 54321
Mend whats wrong 24
6

Whats wrong with my Vokera 24 compact?

I have just had trouble with the pressure release valve with water coming out the over flow everytime the heat... [Read more]
Mend problem 18 months
7

Ravenheat CSI 85 no DHW unless CH on?

Hi, I have a problem with a Ravenheat CSI 85 (18 months old) which will only give DHW when the CH is on. ... [Read more]
Mend worcester combi boiler works
1

Low Pressure Problems on Worcester 28i Combi Boiler?

I have recently moved into a new property but the Worcester 28i Combi boiler seems to have problems with press... [Read more]
Mend boiler too high
3

ikon-t boiler pressure too high?

When i turn my heating on and turn the temp up, the pressure goes from 1.5bar all the way up to 3bar causing t... [Read more]
Mend combi boiler keeps cutting out
2

Worcester Bosch Combi 350 Boiler keeps cutting out?

Hi there, We have the above named boiler and have had 2 WB technicians in this week to look at it and neith... [Read more]
Mend boiler hot water downstairs
1

How can I fix my Vaillant Turbomax 282/1E combination boiler?

When I turn on the hot water tap downstairs I cannot get any hot water. On closer investigation the micro-swit... [Read more]
Mend boiler keeps pressure water
2

baxi solo boiler keeps building pressure and puts water outside?

My baxi solo wall mounted boiler is fitted with an expansion tank(red shaped tank with valve). Recently the ov... [Read more]
Mend radiators heat hot water central
2

Baxi 105e - Radiators heat up when dhw flowing?

When hot water (dhw) is flowing then the central heating system heats up as well. The Boiler is set to dhw on... [Read more]
Mend turbomax water boiler
1

Vaillant turbomax 824e not supplying hot water?

hi have a trubomax boiler which when running direct hot water on full setting and tap fully open seems to ... [Read more]
Mend shower combi boiler turn water
1

Mira Shower Excel ?

The shower is conected to combi boiler if I turn off the flow the water still drips fron the shower head, but ... [Read more]
Mend baxi not ignite
2

baxi bahama 100 will not ignite?

I have had the flow valve replaced in the boiler, this being the one that fills the boiler itself. for some re... [Read more]
Mend rsf turn water
3

hi i have a ravenheat boiler rsf 84et not firing up?

when i turn on the hot water or the central heating,the fan starts up and the pilot egnition fires and lights ... [Read more]
Mend pressure help linea
3

No pressure in boiler tried everything, can u help please?

hello, Ive been without central heating for 4 days and its freezing, my boiler is 'vokera linea 24' and th... [Read more]
Mend vaillant hot boiler 824e
20

Vaillant Turbomax plus combi - CH runs when hot tap turned on?

I have a Vaillant Turbomax plus combi boiler - either the 824E or 828E, I cannot currently see which. I hav... [Read more]
Mend potterton puma 80
2

Potterton Puma 80?

With the heating on my boiler keeps turning its self on and off all day it will only run for 35secs then shuts... [Read more]
Mend boiler help rs
4

My CH boiler keeps blowing out when its windy outside!?

Hi, I hope someone can help me with this one. I have an old Baxi Wm 381 RS CH boiler in a house we just moved ... [Read more]
Mend potterton heating gas boiler
2

How can I fix my potterton netaheat electronic 10/16?

When I turn my heating on the Gas boiler fires up and I can hear the pump turn on but none of the radiators he... [Read more]
Mend fault boiler potterton
1

Fault in Boiler Potterton Puma80?

When I turn the heating on the pressure gauge goes up in the red mark area. And the boiler water goes out by t... [Read more]
Mend day heat water
11

Potterton Profile 50e - keeps resetting?

My profile 50e resets itself at least once/twice a day which means I can't rely on it to heat water first thin... [Read more]
Mend will turn off
1

Potterton Gravity Fed but HW will not turn off?

I have a twin pump potterton boiler (it doesn't have a valve fitted to switch between HW/CH independently so I... [Read more]