Recent: Royal 325CX?

Mend 80 Boiler Dhw

Free repair help

We have 30 questions about mending '80 boiler dhw'

How to mend 80 Boiler Dhw

Pages 21
Mend boiler works problem
2

Vokera boiler works in heating mode but not Hot water only mode?

I have a problem with my boiler it is a Vokera 20-80 RS flowmatic. The flowswitch tries to move but does not o... [Read more]
Mend boiler heating chaffoteaux

I have a chaffateux 80 boiler cuts out on CH mode?

I have a chaffateux 80 boiler, the dhw works ok but when CH goes out after a few minutes. It goes back on when... [Read more]
Mend boiler heat exchanger burner
2

How can I fix my Chaffoteaux Britony boiler SE 80?

The hot water, whether the heating is on or off, fluctuates between hot and cold in a 30 odd second cycle. The... [Read more]
Mend central heating hot water flow switch
2

Potterton Puma 80 - No hot water?

Potterton Puma 80 works fine with central heating, but without CH on, it does not produce hot water. At hot wa... [Read more]
Mend 80 boiler dhw

How do I stop my Ferroli Modena 80 E gas boiler sparking once it is lit ?

The boiler recently stopped firing up on DHW and CH. When I moved the flame sensor electrode cable at the main... [Read more]
Mend hot above 60
2

How do I increase my combi boiler hot water temperature above 60*?

Ferolli Maxima 35C. Good animal, had it for 3 years but it niggles me that the DHW is limited to about 60 deg... [Read more]
Mend boiler heating ferroli
1

ferolli modena 80 fan?

Hi my boiler has been working fine until to-night when the fan will not switch off without a reset. CH and DHW... [Read more]
Mend boiler combi heating
2

vokera 80 e combi boiler no hot water?

You have told me that the problem could a faulty flow valve. I have just had the dhw microswitch replaced, is... [Read more]
Mend boiler central heating fault
1

no hot water protherm 80?

protherm 80 boiler intermittent fault on hot water, sometimes fires up fine and sometimes doesn't fire up wh... [Read more]
Mend boiler heating baxi
1

baxi 80 eco boiler cant stop ch coming on?

HI I CANT STOP MY BAXI 80ECO BOILER FROM ACTIVATING THE CH , EVEN IF I ONLY HAVE DHW SELECTED. COULD THE SELE... [Read more]
Mend boiler heating combi
1

potterton combi 80 pump stops when hot?

my boiler runs ok for DHW had new divertor valve last year and flushed. CH starts runs for 20 mins, rads get h... [Read more]
Mend boiler pressure ignition
5

Is my Fan faulty?

After having problems with my boiler not supplying any DHW or CH the last couple of days i am of the opinion i... [Read more]
Mend combi boiler hot water heating
1

Britony Combi 80 DHW Tepid?

My Britony Combi 80 won't heat the domestic hot water to the correct temp. Tepid only. The boiler kicks in ok ... [Read more]
Mend combi boiler no power pcb
4

ferroli modena 80 e blowing fuses and no power to fan?

I have a 5 year old ferroli modena 80 e combi boiler and it recently stopped working. Checked the fuse on the ... [Read more]
Mend boiler pressure expansion vessel
3

water pressure always on move?

Hi it's a vokera 80-20 flowmatic. good old girl not without her problems. can someone advise me as to why th... [Read more]
Mend combi heating repair
2

i have a glow worm swift flow 80 combi boiler, need help to repair?

dhw was intermittent and now i'm lucky if the heater fires up at all the pilot light is ok , i have fitted a n... [Read more]
Mend boiler heating gas valve
1

Ferroli modena 80e 80 e HELP AGAIN !!!!!!?

ok, eventually i got fed up and called out british gas, fixed charge call out they replaced my gas valve (got... [Read more]
Mend heating boiler dhw
1

how can i get my sime 80 friendly format to ignite?

how can i get my sime 80 friendly format to ignite . I am quite familiar with parts of the boiler but it just ... [Read more]
Mend switched diverter valve
3

Puma 80 overheats and shutsdown when DHW switched off?

This 8 year old Potterton Puma 80 has had first a new diverter valve fitted, and now a circuit board, but stil... [Read more]
Mend boiler heating hot water
2

DHW pressure dropping after tap turned on?

Boiler: Baxi Genesis 80. About 15-45 seconds after the hot tap is turned on the flow will slow to a trickle a... [Read more]
Pages 21

Free repair help and information

howtomendit.com find out how to mend just about anything.
Ask Question