Mend 80 combi system
1

What is the matter with my Potterton Puma 80 Combi Boiler system?

I've Recently moved into my new flat and have been unable to get the boiler system to function properly. I am... [Read more]
Mend water turn tap burner
2

My vokera 80 sp combi has no hot water but heating is ok?

when i turn a hot tap on the burner lights as if it is heating the water but there is no hot water at the tap.... [Read more]
Mend boiler main burner
1

Baxi 105e c/heating cycling?

The boiler seems to be heating in bursts. The main burner is only lighting for a few seconds and then shuts o... [Read more]
Mend problem works sound
4

Baxi bahama 100 combi problem?

Hot water works fine but it sound like the fan or pump keeps running after taps turned off. when the boiler... [Read more]
Mend combi heating burner
1

linea 28 no hot water?

i have a linea 28 combi heating is ok but not bringing burner in when hot tap turned on.if switch is turned to... [Read more]
Mend boiler turn heating
1

How can I fix my boiler Baxi 80e?

Turn on boiler,(if either select hot water only or heating and hot water is the same)because the failure red l... [Read more]
Mend oil boiler water
5

myson velaire standard domestic oil boiler keeps cutting out?

AFTER INITIAL START UP THE BOILER KEEPS CUTTING OUT. THE WATER RUNS COLD BEFORE BURNER STARTS AGAIN, RADIATORS... [Read more]
Mend ariston hot water
2

Ariston Eurombi A/23 MFFI burner goes out after 1-2 minutes?

When I turn on the hot water or heating, the burner lights and is fine for a minute or two but then it goes ou... [Read more]
Mend puma 80e combi
1

Potterton Puma 80E Combi overheats and trips out on hotwater cycle?

When the hot water is adjusted or moved from its minimum setting the boiler trips out. Why? Almost every part... [Read more]
Mend solo pf problem
10

Baxi Solo 50/4 Wall Mounted PF Burner Shutdown Problem?

My Baxi Solo 50/4 Wall Mounted PF gas fired central heating boiler ignites when the thermostat calls for heat,... [Read more]
Mend boiler starts running
3

Potterton Puma 80 firing on and off?

My Potterton Puma 80 comi boiler starts firing on and off after it has been running for a few minutes - both h... [Read more]
Mend fault combi heating
2

Fault with Ravenheat Combi boiler (heating goes off)?

I have a Ravenheat Combi boiler which provides hot water ok. However, when the central heating is switched on,... [Read more]
Mend boiler hot water problem
1

How can I fix my Worcester Bosch 240 combi boiler hot water problem?

i have a worcester bosch 240 combi boiler aprox 10 years old. my heating works fine but my hot water seems to ... [Read more]
Mend bosch combi boiler water
2

Bosch Combi boiler 240 ignites and burn gas - no hot water at all?

Hi I have a Worcester Bosch 240i Combi boiler the electronics seems to work fine. When open tap it ignites... [Read more]
Mend hot water hello luke
18

My Potterton Performa 24, No Hot water, NoHeating?

Hello, just moved in and I was trying to understand why I was only getting luke warm waterfrom my boiler. I wa... [Read more]
Mend worm compact boiler
1

How can i fix my glow worm compact electronic combi boiler?

I have a glow worm compact electronic combi boiler which, when I turn it on ignites the burner and heats the h... [Read more]
Mend boiler mode turns
1

Ariston boiler microgenus 27 burner heats to max?

My Ariston microgenus 27 MFFI, gets into a mode where it turns on burner until all yellow leds are lit (80') b... [Read more]
Mend 2 70 boiler
1

What's wrong with my Baxi Solo 2 PF 70 boiler?

We have a wall mounted Baxi Solo 2 PF 70 boiler which has just stopped heating the house and we have no hot wa... [Read more]
Mend rsf turn water
3

hi i have a ravenheat boiler rsf 84et not firing up?

when i turn on the hot water or the central heating,the fan starts up and the pilot egnition fires and lights ... [Read more]
Mend hot running tap cold
3

Worcester 28CDi Intermittant hot water?

When running hot tap hot water keeps going cold for a few seconds then comes back on. Watching the lights on f... [Read more]