how to mend it - Fix appliances, electricals, gadgets, cars... Ask for free help
:: home
:: add a question
:: search
:: help
:: most recent
:: unanswered
   Search: Go 
Fixed for free!
Ask Your Question
Popular

These categories may also be of interest ...

Security Systems, Car Alarm Systems

Full list

... mend, fix, or repair just about anything.

Help someone
  Are you good at fixing things?  

Click here to help

Fault info.
Click here for Delonghi repair information.
First time?

howtomendit.com costs nothing to use and you can ask a question without an account or logging in.

Click here to ask a question.

Answers

Who answers the questions?

Other users of howtomendit.com provide the answers. The more detail and information you provide in your question the easier it is for others to help you.

Search for a fix
How can I fix my
Home Alarm System?
Mend it
How can I mend my Indesit dishwasher?
Categories > Mend Security Systems, Home Alarm Systems > Question
Q & As - mend, repair, fix security systems, home alarm systems, intruder alarms, burglar alarms, wireless, wired, alarm, sensor, sound, trigger, false alarms, siren, remote control, key code, pinNavigate to ...
Security Systems, Home Alarm Systems (6057 other questions)
Other categories
Add a question



Mend > Home Alarm Systems

Question - mend, repair, fix

Veritas r8 ?

On the control pad no 6 when pressed sticking not bleeping when press, unable to set alarm. How can I change my code when I need to press no 6, to change my code to a new one. Can I get round this or do I need to by a new pad



William
October 2017


Need to mend your Veritas R8 home alarm system?

To add an answer, click here To add a new question, click here To find all other questions, click here

Answers - mend, repair, fix

Sorry a little mistake near the end of my answer the user code is 4321 I have put 1234 but (1234 is the factory engineer code) when doing the user code changes from factory settings make sure you use 4321.
Sorry for mistake

Paul m
November 2017

There is a way round it but it is quite a process, obviously you can't do it by the normal code change way and won't be able to do it by the program mode way as you need to enter your original code.
So there's two ways to do it try this way first, enter the 4 digit engineer code (factory set to 1234, press prog button, all the zone lights should be lit if so then enter 07 the zone lights will disappear, then press prog button again, the system will chime to confirm all the settings have reverted back to factory settings and reloaded the NVM (non volatile memory) if this way has worked then the user code will be 4321 if this way works then you would just do the normal steps for a new code change but obviously without the number 6 in your new code.
If the above process doesn't work then the other only way is a factory reset which means accessibility to the main panel i.e.. (where all of your alarm cables/power supply is connected)
Right so if there is a electrical protection supply for the alarm i.e. an electrical spur (which you should really have installed if it was done by a combatant person) switch this off to kill the supply to the panel if not open up the main alarm system box,(please take care as there'll be a live electrical supply connected, to the bottom left there's a transformer and just above to the right of it is where the quick blow fuse for the supply which is in a little black/grey pullout holder carefully pull this out which will kill the mains supply, then disconnect one of the battery leads anyone will do black or red.
Then connect the battery lead back and within 5sec press and release the tamper spring on the pub board 3times each time you press and release it you should hear a beep, after the 3rd press the alarm should start up beeping as if it would if you were if you were entertaining the house/premises i.e.. entry/exit mode, then quickly go to the keypad and enter the factory user code 1234 the alarm should stop, then the tamper circuit will flash as you have the lid off the main panel this is normal. Go and Replace the lid back being carefull as if you lift it on and off you will set the alarm off as the tamper circuit/spring is still active if you do accidentally do this just enter the user code to stop the alarm, once the main lid is on go to the keypad and press reset button two times and this should clear the tamper light and only have the day/unset/ power light on.
Then just do the the normal user code change process using the 1234 code.
Sorry for the waffle on but I wanted to explain in detail as things can easily be missed.
Hope this helps please follow back and let me know how you get/got on.

Paul m
November 2017

To add an answer, click here    

Add An Answer Form

Add your answer using the form below ...

The question: Veritas r8 ?
Your answer:

(Add your answer here. Try to include as much detail as possible.)
Your name:

(Enter your name as you wish it to be displayed.)
Other questions in this category - Security Systems, Home Alarm Systems
Veritas R8 Alarm won't reset but beeps when using the external doors, pleas?

Last week we had a series of power cuts, the Veritas R8 alarm hasn't been used for a long time. When the power went off it kept beeping for 20 minutes then went off. Now the power is back on but it won't reset (the keypad is less responsive and doesn't do much). When we use the front or back door th...

Click here for how to mend it.
veritas r8 alarm as no power on control panal?

I have a veritas alarm and I don't have any power to my control panals...

Click here for the fix.
Can I change user code on a veritas R8 alarm pad?

Is it possible to change the user code on my Veritas R8 keypad...

Click here for the fix.
Veritas r8 bleeps ?

My veritas r8 alarm has just started bleeping Are alarms sensitive to the cold as it mounted on a external wall in our down stairs cupboard....

Click here for the repair.
Texecom Alarm System.?

I have Texecom Veritas R8 Plus alarm keypad. This morning it kept beeping. I thought it was due to a possible power cut . But not so. I put in my code and pressed reset. The beeping has stopped but unset light now keeps flashing....

Click here for the repair.
How can I Part set my Texicom Veritas R8 control panel ?

My Veritas R8 alarm control panel is not allowing me to to " Part set" or " Omit" zones despite following correct instructions in guide book ....

Click here for how to mend it.
I have a flashing green light on my veritas r8 control panel?

This green light is flashing on both panel and box how can I sort it out coz I'm worried now I can't use the alarm ? It's a veritas R8 alarm...

Click here for the fix.
Why isn't the external sounder going off when the part set alarm goes off?

I have installed a veritas r8 alarm in a clients house with a PIR in the garage and 3 PIR's in the house. Everything is working fine on full set but when the alarm is part set for the garage PIR the external sounder (bell box) doesn't sound when triggered. How can I get it to work? The alarm in the ...

Click here for the repair.
Fix what?
Household Appliances, Vacuum Cleaners - fix/mend/repair/service information
Audio, Minidisc Players - fix/mend/repair/service information
Bathroom Appliances, Baths and Showers - fix/mend/repair/service information
Help wanted!
Advertisements
Fixed!
Can't believe the method worked, but it really did! Thank you.

Rachel
Dec 2019


Mend it
How can I fix my phone's keypad?
All appliances!

To mend any household, kitchen, or other electrical appliance start here.

To search for repair advice click here.

To find out how to mend it click here.

Mend it
How can I correct an engine missfire?
Fault find
Click here to fix Pioneer products.
Advertisements
Important

Attempting repairs can be dangerous.
In many instances work should only be undertaken by a qualified professional.
Ensure you have read our Small Print page before using information supplied via this website.

©  2003 vE
We use Cookies. See our Privacy Policy.