Glow-worm economy 50 works with cover removed only?

my Glow-worm 50 stopped firing up when heating was called for.the fan is fine and the sensor tubes were blown through and it started working fine.however when i replace the outside cover it stopped responding again.took it off and its fine...any suggestions

john walsh
February 2013
its a fault finding issue u will need to eliminate each issue to find the problem. by opening the cover u are allowing an increased amount of air into the chamber so u get a higher airflow causing the air pressure switch to operate.
it could be as follows.
1) check voltage at fan see if its getting 230v . if its below 200v its a fault control board not allowing the fan at full as it should.
2) faulty air pressure switch
3) blocked holes where the plastic tubes join on to give these areas a good clean as a reduced flow will affect it.
4) worn out fan not sucking enough air

kash
February 2013

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Cover Stopped Heating

Mend Heating, Home Heating Systems
Click here to mend Glow-Worm home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Click here to mend Glow-Worm home heating systems