intermittant fault on ravenheat csi85at?

on this combi when switched to hot water only boiler does not fire at all.on winter /summer boiler fires on hot water but only when heating called. turn on the heating sometimes the boiler fire's but will go to lockout at varying times and some times straight to lock out after 5 to 10 seconds.i have fitted a new thermistor to hot water side and new air pressure switch still have same problem spoke to ravenheat they said requires new pcb. anyone had the same problem thanks

mpg plumb
December 2011
With thw boiler switched off
Take the plastic cover off the microswitch on the side of the diverter valve. Turn on the hot water tap. Look to see if the diverter valve pushes out to press the switch. Mine wasn't coming out far enough to press the switch so never fired the boiler for hot water. I dropped a rubber washer in front of it and it now works. I will clean out the diverter valve at some point as this is the cause. (In my case)

Nick
January 2012

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Hot Water Boiler Fire

Mend Heating, Home Heating Systems
Mend repair fix Ravenheat home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Ravenheat home heating systems